Fluke 117 True RMS multimeter

    • SKU: Fluke-117
    • Brand: Fluke
    • Availability: In Stock

    Fluke 117 True RMS multimeterPowerpro company Limited is the distributor, supplier and service provider of ( Test Equipment Product Sales, Test Equipment Calibration, Test Equipment Rentals and Product Training) in Nigeria. Product overview: Fluke 117 Electricians Multimeter with Non-Contact voltage Fluke 117 Digital Multimeter for Electricians with Non-Contact voltage This...



    Add to quote

    Fluke 117 True RMS multimeter

    Powerpro company Limited is the distributor, supplier and service provider of ( Test Equipment Product Sales, Test Equipment Calibration, Test Equipment Rentals and Product Training) in Nigeria.

    Product overview: Fluke 117 Electricians Multimeter with Non-Contact voltage

    Fluke 117 Digital Multimeter for Electricians with Non-Contact voltage

    This Digital Multimeter includes integrated non-contact voltage detection to help get the job done faster.

    The Fluke 117 Digital Multimeter includes integrated non-contact voltage detection and Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage. It is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools and helps get the job done faster.

    Users around the world have said their 117 digital multimeter is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.

    The Fluke 110 Series has five true-rms digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.

    Other useful features:

    • Accurate, easy-to-use multimeter with integrated VoltAlert™ technology for non-contact voltage detection
    • Features AutoVolt automatic AC/DC voltage selection
    • Provides low input impedance to help prevent false readings due to ghost voltage
    • Presents a large white LED backlight for working in poorly lit areas
    • Features True RMS capabilities for accurate measurements on non-linear loads
    • Measures 10 A (20 A overload for 30-seconds)
    • Measures resistance, continuity, frequency, and capacitance
    • Provides Min/Max/Average to record signal fluctuations
    • Comes with an holster with probe holders for easy storage
    • Features compact ergonomic design for one-handed operation
    • Fits into optional ToolPak™ magnetic hanger for hands-free operation
    • CAT III 600 V safety rated
    • A large white LED backlight to improve measurement visibility in poorly lit areas
    • VoltAlert™ technology for fast, go/no go non-contact voltage detection
    • AutoVolt and low input impedance modes to provide faster, more accurate readings
    • For commercial electricians, commercial and residential electrical work

    Includes:

    • 4 mm silicone test lead set
    • Holster
    • User manual

    Specifications: Fluke 117 Electricians Multimeter with Non-Contact voltage

    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Safety IEC 61010-1: Pollution Degree 2
    IEC 61010-2-033: CAT III 600V
    Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
    Display Digital: 6,000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Battery type 9 volt Alkaline, IEC 6LR61
    Battery life 400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts Range/resolution 600.0 mV / 0.1 mV
    Accuracy ±([% of reading] + [counts]): 0.5% + 2
    DC volts Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy ±([% of reading] + [counts]): 0.5% + 2
    Auto volts Range/resolution 600.0 V / 0.1 V
    Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
    AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    Continuity Range/resolution 600 Ω / 1 Ω
    Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
    500 μs or longer.
    Ohms Range/resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy 0.9% + 1
    Range/resolution 40.00 MΩ / 0.01 MΩ
    Accuracy 5% + 2
    Diode test Range/resolution 2.00 V / 0.001 V
    Accuracy 0.9% + 2
    Capacitance Range/resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy 1.9% + 2
    Range/resolution > 1000 μF
    Accuracy 5% + 20%
    Lo-Z capacitance Range 1 nF to 500 μF
    Accuracy 10% + 2 typical
    AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A
    10.00 A / 0.01 A
    Accuracy 1.5% + 3
    20 A continuous overload for 30 seconds max
    DC amps Range/resolution

    6.000 A / 0.001 A   10.00 A / 0.01 A

    Accuracy 1.0% + 3
    20 A continuous overload for 30 seconds max
    Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 Hz
    50.00 kHz / 0.01 Hz
    Accuracy 0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
    Mechanical and General Specifications
    Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight 550 g
    Warranty 3 years