Buy Fluke 1524 Reference Thermometer, 2-channel| Powerpro Nigeria

    • SKU: 1524
    • Brand: Fluke
    • Availability: In Stock

    Fluke 1524 Reference Thermometer, 2-channelDesigned for the multi-tasker, this single-channel thermometer measures, graphs, and records PRTs, thermocouples, and thermistors with one tool. Delivering high accuracy, wide measurement range, logging, and trending, all in a handheld device you can take anywhere.Fluke 1524 Offers Using a technique called a current reversal, this...



    Add to quote

    Fluke 1524 Reference Thermometer, 2-channel

    Designed for the multi-tasker, this single-channel thermometer measures, graphs, and records PRTs, thermocouples, and thermistors with one tool. Delivering high accuracy, wide measurement range, logging, and trending, all in a handheld device you can take anywhere.

    Fluke 1524 Offers

    Using a technique called a current reversal, this reference thermometer eliminates thermal EMFs, for precision temperature measurements. Special precision resistors and a highly stable reference voltage source maintain this reference thermometer's accuracy virtually insensitive to environmental temperature. Additionally, it can endure rigorous testing in temperature extremes and under harsh conditions of vibration, allowing professionals to take them anywhere they need to go.

    Features

    • High accuracy
    • Two channels; memory for logging 15,000 measurements
    • Real-time clock for time and date stamps
    • Three sensor types (PRTs, thermocouples, and precision thermistors)
    • Fast mode
    • Backlit LCD graphic display
    • Plot and scale trends in real time
    • Simultaneous dual channel readings

    INFO-CON connectors ensure correct temperature conversion

    Inside the INFO-CON, a memory chip keeps calibration information for the attached probe. Simply plugging in the probe uploads the information to the readout, ensuring the correct temperature conversion for accurate, hassle-free measurements.

    Probes may be locked by password to specific channels and readouts for security or for system calibration traceability. Plug any thermocouple with mini-thermocouple jacks into an optional universal thermocouple adapter for convenient measurement. Each thermocouple adapter or standard connector supports reference junction compensation (RJC) with its own internal precision thermistor.

    Monitor trends in the lab or in the field

    See trends graphically on the thermometer's 128 x 64 backlit LCD display. You can change the graph's resolution at the touch of a button. Now it's easy to see when the temperature is stable, without statistics or long delays, or monitor processes over time to verify correct operation.

    Document on demand up to 25 readings and associated statistics for easy retrieval. You can view the data through the display or by uploading it to a PC via RS-232 connection and 9940 software, included free. To monitor and log more data over time, use a PC and optional LogWare II software.

    RS-232-to-USB adapters are available for those who prefer USB connectors. Battery power lasts at least 20 hours on three AA batteries, or use the dc power adapter for extended periods of measurement. Power saving features can be enabled or disabled for longer battery life or greater convenience.

    Applications

    • Calibration
    • Loop checking
    • Plant startup
    • Troubleshooting
    • Maintenance
    • Repair
    • Baths
    • Dry-block calibrators
    • Thermowells
    • Clean rooms
    • Engines
    • Heat exchangers
    • Furnaces
    • Freezers

    Fluke 1524 Offers

    Using a technique called a current reversal, this reference thermometer eliminates thermal EMFs, for precision temperature measurements. Special precision resistors and a highly stable reference voltage source maintain this reference thermometer's accuracy virtually insensitive to environmental temperature. Additionally, it can endure rigorous testing in temperature extremes and under harsh conditions of vibration, allowing professionals to take them anywhere they need to go.

    Features

    • High accuracy
    • Two channels; memory for logging 15,000 measurements
    • Real-time clock for time and date stamps
    • Three sensor types (PRTs, thermocouples, and precision thermistors)
    • Fast mode
    • Backlit LCD graphic display
    • Plot and scale trends in real time
    • Simultaneous dual channel readings

    INFO-CON connectors ensure correct temperature conversion

    Inside the INFO-CON, a memory chip keeps calibration information for the attached probe. Simply plugging in the probe uploads the information to the readout, ensuring the correct temperature conversion for accurate, hassle-free measurements.

    Probes may be locked by password to specific channels and readouts for security or for system calibration traceability. Plug any thermocouple with mini-thermocouple jacks into an optional universal thermocouple adapter for convenient measurement. Each thermocouple adapter or standard connector supports reference junction compensation (RJC) with its own internal precision thermistor.

    Monitor trends in the lab or in the field

    See trends graphically on the thermometer's 128 x 64 backlit LCD display. You can change the graph's resolution at the touch of a button. Now it's easy to see when the temperature is stable, without statistics or long delays, or monitor processes over time to verify correct operation.

    Document on demand up to 25 readings and associated statistics for easy retrieval. You can view the data through the display or by uploading it to a PC via RS-232 connection and 9940 software, included free. To monitor and log more data over time, use a PC and optional LogWare II software.

    RS-232-to-USB adapters are available for those who prefer USB connectors. Battery power lasts at least 20 hours on three AA batteries, or use the dc power adapter for extended periods of measurement. Power saving features can be enabled or disabled for longer battery life or greater convenience.

    Applications

    • Calibration
    • Loop checking
    • Plant startup
    • Troubleshooting
    • Maintenance
    • Repair
    • Baths
    • Dry-block calibrators
    • Thermowells
    • Clean rooms
    • Engines
    • Heat exchangers
    • Furnaces
    • Freezers

    You can use this tab for adding shipping details, return policies and information or measurements etc.