Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature AccuracyThis tweener thermistor thermometer readout is sensitive to changes in temperature, boasts a fast response time and is suitable for a variety of applications.Fluke 1504-156 Specifications Temperature Range Any thermistor range Resistance Range 0W to 1mW, auto-ranging Probe Thermistors Characterizations...
Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature Accuracy
This tweener thermistor thermometer readout is sensitive to changes in temperature, boasts a fast response time and is suitable for a variety of applications.
Fluke 1504-156 Specifications
Temperature Range | Any thermistor range |
Resistance Range | 0W to 1mW, auto-ranging |
Probe | Thermistors |
Characterizations | Steinhart-Hart thermistor polynomial; Callendar-Van Dusen: R0, a, d and b |
Resistance Accuracy (PPM Of Reading) | 0W to 5kW: 0.5W; 5 to 200kW: 100ppm; 200kW to 1mW: 300ppm |
Temperature Accuracy | ±0.002°C at 0°C; ±0.002°C at 25°C; ±0.004°C at 50°C; ±0.010°C at 75°C; ±0.020°C at 100°C (using 10kW thermistor sensor, a=0.04; does not include probe uncertainty or characterization errors) |
Operating Temperature Range | 55.4 to 91.4°F (13 to 33°C) |
Resistance Resolution | 0W to 10kW: 0.01W; 10 to 100kW: 0.1W; 100kW to 1mW: 1W |
Temperature Resolution | 0.0001°C |
Excitation Current | 2 and 10mA, automatically selected |
Measurement Period | 1 second |
Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) |
Probe Connection | 4-wire with shield, 5-pin DIN connector |
Communications | RS-232 serial standard; IEEE-488 (GPIB) optional |
Display | 8-digit, 7-segment, yellow-green LED; 0.5in high characters |
Power | 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify |
Size (H x W x D) | 2.4 x 5.6 x 7.1in (61 x 143 x 181mm) |
Probes From Hart | 5640-44, 5610-65 |
Calibration | ISO 17025-accredited calibration provided |
Fluke 1504-156 Specifications
Temperature Range | Any thermistor range |
Resistance Range | 0W to 1mW, auto-ranging |
Probe | Thermistors |
Characterizations | Steinhart-Hart thermistor polynomial; Callendar-Van Dusen: R0, a, d and b |
Resistance Accuracy (PPM Of Reading) | 0W to 5kW: 0.5W; 5 to 200kW: 100ppm; 200kW to 1mW: 300ppm |
Temperature Accuracy | ±0.002°C at 0°C; ±0.002°C at 25°C; ±0.004°C at 50°C; ±0.010°C at 75°C; ±0.020°C at 100°C (using 10kW thermistor sensor, a=0.04; does not include probe uncertainty or characterization errors) |
Operating Temperature Range | 55.4 to 91.4°F (13 to 33°C) |
Resistance Resolution | 0W to 10kW: 0.01W; 10 to 100kW: 0.1W; 100kW to 1mW: 1W |
Temperature Resolution | 0.0001°C |
Excitation Current | 2 and 10mA, automatically selected |
Measurement Period | 1 second |
Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) |
Probe Connection | 4-wire with shield, 5-pin DIN connector |
Communications | RS-232 serial standard; IEEE-488 (GPIB) optional |
Display | 8-digit, 7-segment, yellow-green LED; 0.5in high characters |
Power | 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify |
Size (H x W x D) | 2.4 x 5.6 x 7.1in (61 x 143 x 181mm) |
Probes From Hart | 5640-44, 5610-65 |
Calibration | ISO 17025-accredited calibration provided |