Fluke 1502A-156 Thermometer Readout, Tweener PRT, ±0.006°C at 0°C Temperature AccuracyThis tweener thermometer readout accurately measures the resistance of the probe and then converts the resistance to a temperature value using built-in algorithms.Fluke 1502A-156 Specifications Temperature Range -200 to 962°C (-328 to 1764°F) Resistance Range 0 to 400W, auto-ranging Probe...
Fluke 1502A-156 Thermometer Readout, Tweener PRT, ±0.006°C at 0°C Temperature Accuracy
This tweener thermometer readout accurately measures the resistance of the probe and then converts the resistance to a temperature value using built-in algorithms.
Fluke 1502A-156 Specifications
Temperature Range | -200 to 962°C (-328 to 1764°F) |
Resistance Range | 0 to 400W, auto-ranging |
Probe | Nominal RTPW: 10 to 100W RTD, PRT or SPRT |
Characterizations | ITS-90 subranges 4, 6, 7, 8, 9, 10 and 11; IPTS-68: R0, a, d, a4 and c4; Callendar-Van Dusen: R0, a, d and b |
Resistance Accuracy (PPM Of Reading) | 0 to 20W: 0.0005W; 20 to 400W: 25ppm |
Temperature Accuracy | ±0.004°C at -100°C; ±0.006°C at 0°C; ±0.009°C at 100°C; ±0.012°C at 200°C; ±0.018°C at 400°C; ±0.024°C at 600°C |
Operating Temperature Range | 60.8 to 86°F (16 to 30°C) |
Resistance Resolution | 0 to 20W: 0.0001W; 20 to 400W: 0.001W |
Temperature Resolution | 0.001°C |
Excitation Current | 0.5 and 1mA, user selectable, 2Hz |
Measurement Period | 1 second |
Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) |
Probe Connection | 4-wire with shield, 5-pin DIN connector |
Communications | RS-232 serial standard; IEEE-488 (GPIB) optional |
Display | 8-digit, 7-segment, yellow-green LED; 0.5in high characters |
Power | 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify |
Size (H x W x D) | 2.4 x 5.6 x 7.1in (61 x 143 x 181mm) |
Probes From Hart | 5615, 5627, 5626, 5628, 5622 |
Calibration | ISO 17025-accredited calibration provided |
Fluke 1502A-156 Specifications
Temperature Range | -200 to 962°C (-328 to 1764°F) |
Resistance Range | 0 to 400W, auto-ranging |
Probe | Nominal RTPW: 10 to 100W RTD, PRT or SPRT |
Characterizations | ITS-90 subranges 4, 6, 7, 8, 9, 10 and 11; IPTS-68: R0, a, d, a4 and c4; Callendar-Van Dusen: R0, a, d and b |
Resistance Accuracy (PPM Of Reading) | 0 to 20W: 0.0005W; 20 to 400W: 25ppm |
Temperature Accuracy | ±0.004°C at -100°C; ±0.006°C at 0°C; ±0.009°C at 100°C; ±0.012°C at 200°C; ±0.018°C at 400°C; ±0.024°C at 600°C |
Operating Temperature Range | 60.8 to 86°F (16 to 30°C) |
Resistance Resolution | 0 to 20W: 0.0001W; 20 to 400W: 0.001W |
Temperature Resolution | 0.001°C |
Excitation Current | 0.5 and 1mA, user selectable, 2Hz |
Measurement Period | 1 second |
Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) |
Probe Connection | 4-wire with shield, 5-pin DIN connector |
Communications | RS-232 serial standard; IEEE-488 (GPIB) optional |
Display | 8-digit, 7-segment, yellow-green LED; 0.5in high characters |
Power | 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify |
Size (H x W x D) | 2.4 x 5.6 x 7.1in (61 x 143 x 181mm) |
Probes From Hart | 5615, 5627, 5626, 5628, 5622 |
Calibration | ISO 17025-accredited calibration provided |