Fluke 438-II/BASIC Power Quality &motor Analyzer, without clamps and FC WiFi SD Card

    • SKU: Fluke-438-II/BASIC
    • Brand: Fluke
    • Availability: In Stock

    Fluke 438-II/BASIC Power Quality &motor Analyzer, without clamps and FC WiFi SD CardPowerpro company Limited is the distributor, supplier and service provider of ( Test Equipment Product Sales, Test Equipment Calibration, Test Equipment Rentals and Product Training) in Nigeria. Product overview: Fluke 438-II Power Quality Analyzer & Motor Analyzer Quickly...



    Add to quote

    Fluke 438-II/BASIC Power Quality &motor Analyzer, without clamps and FC WiFi SD Card

    Powerpro company Limited is the distributor, supplier and service provider of ( Test Equipment Product Sales, Test Equipment Calibration, Test Equipment Rentals and Product Training) in Nigeria.

    Product overview: Fluke 438-II Power Quality Analyzer & Motor Analyzer

    Quickly and easily discover electrical and mechanical performance of electric motors, and evaluate power quality with a single test tool

    The Fluke 438-II Power Quality and Motor Analyzer adds key mechanical measurement capabilities for electric motors to the advanced power quality analysis functions of the Fluke 435 Series II Power Quality Analyzers  . Quickly and easily measure and analyze key electrical and mechanical performance parameters such as power, harmonics, unbalance, motor speed, torque and mechanical power without the need of mechanical sensors. Fluke 434-II, 435-II and 437-II Power Quality Analyzer users can add motor analysis capabilities to their existing units with the Fluke-438-II/MA Motor Analyzer upgrade kit. The 438-II uses data from the motor rating plate for either NEMA or IEC rated motors to aid the calculation of the mechanical parameters.

    Other useful features:

    • Calculates mechanical power and efficiency without mechanical sensors. Just connect to the input conductors
    • Measures electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency
    • Identify power quality issues such as dips, swells, transients, harmonics and unbalance
    • Uses PowerWave data capture to capture fast RMS data, and show half-cycle averages and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)
    • Offers waveform capture function to capture 100/120 cycles (50/60 Hz) of each detected event, in all modes, without set-up
    • Uses automatic transient mode to capture waveform data at 200 kS/s on all phases simultaneously up to 6 kV
    • Automatically calculate motor derating according to NEMA/IEC guidelines
    • Fluke Connect® compatible so you can view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software

    Key features

    The 438-II Power Quality Analyzer & Motor Analyzer helps you effectively evaluate electrical and mechanical performance just by hooking up voltage and measuring current, providing you with an unprecedented level of data.

    • Brings key motor analysis parameters like speed, torque and mechanical power and calculates motor efficiency without mechanical sensors
    • Includes full power quality and electrical energy analyzer functionality
    • Highest safety rating in industry; 1000 V CAT III / 600 V CAT IV

    Specifications: Fluke 438-II Power Quality Analyzer & Motor Analyzer

    Amps (accuracy excluding clamp accuracy)

    Drive Measurement Details
    Motor Type 3 phase asynchronous (induction)
    Power Source Variable Frequency Drive
    Motor Frequency Range 40Hz to 70Hz
    Over/Under Voltage from Nominal V/f Curve (%) -15% to +15%
    Carrier Frequency Range 2.5kHz–20kHz
    Variable speed drive technology that is covered by the 438-II
    Inverter Type VSI only (voltage controlled) *
    Control Method V/f control, open-loop vector, closed loop vector, drives with encoders.
    Frequency 40 to 70 Hz
    * VSI drives are the most common drives. The alternative CSI drives are used in higher power applications.
    Variable speed drive technology NOT covered by the 438-II
    Inverter Type CSI (current source inverter)
    Motors type Synchronous (DC, stepper, permanent magnet etc.)
    Motor Frequency <40 and >70 Hz
    Mechanical specifications
    Mechanical measurements can be performed on direct online motors with a 3 wire connection.
    Motor measurement
      Range Resolution Accuracy Default limit
    Mechanical motor

    Power
    0.7 kW to 746 kW

    1 hp to 1000 hp
    0.1 kW

    0.1 hp
    ±3% 1

    ±3% 1
    100% = rated power

    100% = rated power
    Torque 0 Nm to 10 000 Nm

    0 lb ft to 10 000 lb ft
    0.1 Nm

    0.1 lb ft
    ±5% 1

    ±5% 1
    100% = rated torque

    100% = rated torque
    rpm 0 rpm to 3600 rpm 1 rpm ±3% 1 100% = rated rpm
    Efficiency 0% to 100% 0.10% ±3% 1 NA
    Unbalance (NEMA) 0% to 100% 0.10% ±0.15% 5%
    Harmonics Voltage
    Factor (NEMA)
    0 to 0.20 0.1 ±1.5% 0.15
    Unbalance Derating
    Factor
    0.7 to 1.0 0.1 indicative NA
    Harmonics Derating
    Factor
    0.7 to 1.0 0.1 indicative NA
    Total NEMA Derating
    Factor
    0.5 to 1.0 0.1 indicative NA
    Notes: Supports motor design types NEMA A, B, C, D & E and IEC type H and N.
    Rated torque is calculated from rated power and rated speed.
    Update rate of Motor Measurements is 1x per second.
    Default Trend duration is 1 week.
    1Add 5% error when selecting Motor design type Other
    Specification valid for Motor Power > 30% of rated power
    Specification valid at stable operating temperature. Run the motor for at least 1 hour at full load
    (2-3 hours if the motor is 50 HP or higher) to obtain stable temperature
    Product Specifications
    Volt Model Measurement Range Resolution Accuracy
    Vrms (AC + DC)   1 V to 1000 V phase to neutral 0.01 V ±0.1% of nominal voltage 1
    Vpk   1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
    Voltage Crest Factor (CF)   1.0 > 2.8 0.01 ±5%
    Vrms½     0.1 V ±0.2% of nominal voltage
    Vfund     0.1 V ±0.1% of nominal voltage
    Amps (AC + DC) i430-Flex 1x  5 A to 6000 A 1 A ±0.5% ±5 counts
    i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
    1mV/A 1x 5 A to 2000 A 1A ±0.5% ±5 counts
    1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
    Apk i430-Flex 8400 Apk 1 Arms ±5%
    1mV/A 5500 Apk 1 Arms ±5%
    A Crest Factor (CF)   1 to 10 0.01 ±5%
    Amps½ i430-Flex 1x 5 A to 6000 A 1 A ±1% ±10 counts
    i430-Flex 10x 0.5 A to 600 A 0.1 A ±1% ±10 counts
    1mV/A 1x 5 A to 2000 A 1 A ±1% ±10 counts
    1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±1% ±10 counts
    Afund i430-Flex 1x 5 A to 6000 A 1 A ±0.5% ±5 counts
    i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
    1mV/A 1x 5 A to 2000 A 1 A ±0.5% ±5 counts
    1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
    Hz
    Fluke 434 @ 50 Hz Nominal 42.50 Hz to 57.50 Hz 0.01 Hz ±0.01 Hz
    Fluke 434 @ 60 Hz Nominal 51.00 Hz to 69.00 Hz 0.01 Hz ±0.01 Hz
    Power
    Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ±1% ±10 counts
    1 mV/A max 2000 MW 0.1 W to 1 MW ±1% ±10 counts
    Power Factor (Cos j/DPF) 0 to 1 0.001 ±0.1% @ nominal load conditions
    Energy
    kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts
    Energy Loss i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts Excluding line resistance accuracy
    Harmonics
    Harmonic Order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
    Inter-Harmonic Order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
    Volts % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
    r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
    Absolute 0.0 to 1000 V 0.1 V ±5% 1
    THD 0.0% to 100% 0.1% ±2.5%
    Amps % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
    r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
    Absolute 0.0 to 600 A 0.1 A ±5% ±5 counts
    THD 0.0% to 100% 0.1% ±2.5%
    Watts % f or r 0.0% to 100% 0.1% ±n x 2%
    Absolute Depends on clamp scaling and V nominal ±5% ±n x 2% ±10 counts
    THD 0.0% to 100% 0.1% ±5%
    Phase Angle -360° to +0° ±n x 1°
    Flicker
    Plt, Pst, Pst (1 min) Pinst 0.00 to 20.00 0.01 ±5%
    Unbalance
    Volts % 0.0% to 20.0% 0.1% ±0.1%
    Amps % 0.0% to 20.0% 0.1% ±1%
    Mains Signaling
    Threshold Levels Threshold, limits and signaling duration is programable for two signaling frequencies
    Signaling Frequency 60 Hz to 3000 Hz 0.1 Hz  
    Relative V % 0% to 100% 0.10% ±0.4%
    Absolute V3s (3 second avg.) 0.0 V to 1000 V 0.1 V ±5% of nominal voltage
    General Specifications
    Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
    Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
    Memory 16GB Wi-Fi SD card for standard models or 8GB SD card for /INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).
    Real-Time Clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture
    Environmental
    Operating Temperature 0°C ~ +40°C; +40°C ~ +50°C excl. battery
    Storage Temperature -20°C ~ +60°C
    Humidity +10°C ~ +30°C: 95% RH non-condensing
    +30°C ~ +40°C: 75% RH non-condensing
    +40°C ~ +50°C: 45% RH non-condensing
    Maximum Operating Altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
    Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
    Maximum storage altitude 12 km (40,000 ft)
    Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
    Interfaces Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
    Warranty Three years (parts and labor) on main instrument, one year on accessories

    1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if < 1% of nominal voltage
    2. 50Hz/60Hz nominal frequency according to IEC 61000-4-30
    3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode
    4. For nominal voltage 50 V to 500 V

    You can use this tab for adding shipping details, return policies and information or measurements etc.