    Fluke 1502A-156 Thermometer Readout, Tweener PRT, ±0.006°C at 0°C Temperature AccuracyThis tweener thermometer readout accurately measures the resistance of the probe and then converts the resistance to a temperature value using built-in algorithms.Fluke 1502A-156 Specifications Temperature Range -200 to 962°C (-328 to 1764°F) Resistance Range 0 to 400W, auto-ranging Probe...



    Add to quote

    Fluke 1502A-156 Thermometer Readout, Tweener PRT, ±0.006°C at 0°C Temperature Accuracy

    This tweener thermometer readout accurately measures the resistance of the probe and then converts the resistance to a temperature value using built-in algorithms.

    Fluke 1502A-156 Specifications

    Temperature Range -200 to 962°C (-328 to 1764°F)
    Resistance Range 0 to 400W, auto-ranging
    Probe Nominal RTPW: 10 to 100W RTD, PRT or SPRT
    Characterizations ITS-90 subranges 4, 6, 7, 8, 9, 10 and 11; IPTS-68: R0, a, d, a4 and c4; Callendar-Van Dusen: R0, a, d and b
    Resistance Accuracy (PPM Of Reading) 0 to 20W: 0.0005W; 20 to 400W: 25ppm
    Temperature Accuracy ±0.004°C at -100°C; ±0.006°C at 0°C; ±0.009°C at 100°C; ±0.012°C at 200°C; ±0.018°C at 400°C; ±0.024°C at 600°C
    Operating Temperature Range 60.8 to 86°F (16 to 30°C)
    Resistance Resolution 0 to 20W: 0.0001W; 20 to 400W: 0.001W
    Temperature Resolution 0.001°C
    Excitation Current 0.5 and 1mA, user selectable, 2Hz
    Measurement Period 1 second
    Digital Filter Exponential, 0 to 60 seconds time constant (user selectable)
    Probe Connection 4-wire with shield, 5-pin DIN connector
    Communications RS-232 serial standard; IEEE-488 (GPIB) optional
    Display 8-digit, 7-segment, yellow-green LED; 0.5in high characters
    Power 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify
    Size (H x W x D) 2.4 x 5.6 x 7.1in (61 x 143 x 181mm)
    Probes From Hart 5615, 5627, 5626, 5628, 5622
    Calibration ISO 17025-accredited calibration provided
    Click here for complete specifications on the Fluke 1502A-156

    Fluke 1502A-156 Specifications

    Temperature Range -200 to 962°C (-328 to 1764°F)
    Resistance Range 0 to 400W, auto-ranging
    Probe Nominal RTPW: 10 to 100W RTD, PRT or SPRT
    Characterizations ITS-90 subranges 4, 6, 7, 8, 9, 10 and 11; IPTS-68: R0, a, d, a4 and c4; Callendar-Van Dusen: R0, a, d and b
    Resistance Accuracy (PPM Of Reading) 0 to 20W: 0.0005W; 20 to 400W: 25ppm
    Temperature Accuracy ±0.004°C at -100°C; ±0.006°C at 0°C; ±0.009°C at 100°C; ±0.012°C at 200°C; ±0.018°C at 400°C; ±0.024°C at 600°C
    Operating Temperature Range 60.8 to 86°F (16 to 30°C)
    Resistance Resolution 0 to 20W: 0.0001W; 20 to 400W: 0.001W
    Temperature Resolution 0.001°C
    Excitation Current 0.5 and 1mA, user selectable, 2Hz
    Measurement Period 1 second
    Digital Filter Exponential, 0 to 60 seconds time constant (user selectable)
    Probe Connection 4-wire with shield, 5-pin DIN connector
    Communications RS-232 serial standard; IEEE-488 (GPIB) optional
    Display 8-digit, 7-segment, yellow-green LED; 0.5in high characters
    Power 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify
    Size (H x W x D) 2.4 x 5.6 x 7.1in (61 x 143 x 181mm)
    Probes From Hart 5615, 5627, 5626, 5628, 5622
    Calibration ISO 17025-accredited calibration provided