Fluke Calibration 5522A Multi-Product Calibrator

  • Fluke Calibration 5522A Multi-Product CalibratorFluke Calibration 5522A Multi-Product CalibratorRobust, transportable wide workload coverage The 5522A Multi-Product Calibrator replaces the 5520A and addresses a wide calibration workload and comes with internal and external protection features that protect it against damage and make it easier to transport for on-site or mobile calibration....



    Add to quote

    Fluke Calibration 5522A Multi-Product Calibrator

    Fluke Calibration 5522A Multi-Product Calibrator

    Robust, transportable wide workload coverage

    The 5522A Multi-Product Calibrator replaces the 5520A and addresses a wide calibration workload and comes with internal and external protection features that protect it against damage and make it easier to transport for on-site or mobile calibration. The 5522A can also be fully automated with MET/CAL® Plus Calibration Management Software (version 7.3 SP1 or later). It is the ideal calibrator for metrology professionals who need to perform resistance calibration, voltage calibration, current calibration and more, and who want a transportable instrument that offers them a high return on investment.

     

    55XXA Multi-Product Calibrators Oscilloscope Calibration Option Specifications

    Summary Specifications

    Function & Range  
    Direct volts 0 to ± 1020 V
    Direct Current 0 to 20.5 A
    Alternating volts 1 mV to 1020 V 
    10 Hz to 500 kHz
    Volt*Hertz 1000 V@ 10 kHz/330 V@100 kHz
    Alternating current 29 μA to 20.5 A 
    10 Hz to 30 kHZ
    Waveforms Sine, square, triangle, truncated sine
    Resistance 0 MΩ to 1100 MΩ
    Capacitance 220 pF to 110 mF
    Power (phantom loads) 20.9 kW
    Phase control 0.01°
    Thermocouple (source and measure temperature) B, C, E, J, K L N R, S, T, U 
    10 μV/°C
    RTD (source temperature) Pt 385-100 Ω, Pt 3926-100 Ω Pt 3916-100 Ω, 
    Pt 385-200 Ω, Pt 385-500 Ω, Pt385 1000 Ω, 
    PtNi 385-120 Ω, (Ni120), Cu 427 10 Ω
    Interfaces RS-232, IEEE 488
    Phase lock Yes
    Frequency uncertainty <2.5 ppm
    External frequency reference (10 MHz) Yes
    Calibration Documentation 17025 accredited report of calibration included
    Oscilloscope calibrator (optional) Levelled sine wave from 5 mV to 5.5 Vpp max, frequencies 50 kHz to 600 kHz and 3.5 Vpp max to 1100 MHz; edge rise times of < 300ps, multiple trigger functions, lowest dc, square wave and timing uncertainty
    Power calibrator (optional) Composite harmonic, flicker simulation, sags and swells simulation modes

    You can use this tab for adding shipping details, return policies and information or measurements etc.