Allen-Bradley 1492-RCDA4B63S Residual Current Device 63 A

  • Allen-Bradley 1492-RCDA4B63S Residual Current Device 63 ADescription1492 SeriesAllen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted.Features & Benefits2 or...



    Add to quote

    Allen-Bradley 1492-RCDA4B63S Residual Current Device 63 A

    Description

    1492 Series


    Allen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted.

    Features & Benefits


    2 or 4 pole versions
    DIN Rail mount
    Screw Terminals

    Allen Bradley RCD, 1kA Residual Breaking Capacity, 18 to 4AWG - 1492-RCDA4B63S


    Safeguard your electrical circuits with this Allen Bradley RCD from Rockwell Automation. It provides reliable protection to wiring, appliances and personnel from damage caused by residual currents. This prevents fire outbreaks and electric shocks. As a type-A device, it trips at 2 to 3 times its rated current of 63A, which means it cuts power instantly in the event of a surge, making it a practical choice for use with sensitive equipment. The RCD can break spikes as high as 1kA, so you can depend on it for optimal performance in settings with high inrushes like production plants and workshops.

    • Compact dimensions of 70 (L) x 88 (W) x 67mm (H) for space-efficient installation in confined setups
    • DIN rail mounting style is simple and tool-free, saving time and effort
    • Mechanical endurance of 20,000 operating cycles for long-term performance
    • Compatible with wire sizes from 18 to 4AWG for versatility

    Standards and Certifications


    • UL 1053
    • CSA-C22.2 No. 144
    • RoHS

    How sensitive is this RCD?


    This device has a trip sensitivity of 100mA, which is useful in commercial and industrial settings where numerous devices with low leakage currents are used.


    Allen Bradley RCBs

    Specifications

    Attribute Value
    Circuit Breaker Type RCD
    Current Rating 63A
    Number of Poles 3P+N
    Trip Sensitivity 100mA
    Tripping Characteristics Type A
    Series 1492-RCDA
    Overall Dimensions 70 x 88 x 75mm
    Reset Actuator Type Toggle Switch
    Mounting Style DIN Rail Mount
    Overall Depth 75mm
    Overall Width 88mm
    Break Time Time Delay
    Overall Length 70mm
    Rated AC Voltage 230 V, 400V
    Terminal Contact Type Screw

    You can use this tab for adding shipping details, return policies and information or measurements etc.