Fluke Calibration 8588A Reference Multimeter
Fluke Calibration 8588A Reference MultimeterStability, simplicity and performance by design The 8588A incorporates exceptional linearity, low noise and stability in the design. This best-in-class long-scale digital reference multimeter guarantees superior 3.5 ppm one-year dc voltage relative accuracy and long-term stability over a wide measurement range and functions. The 8588A contains...
Fluke Calibration 8588A Reference Multimeter
Stability, simplicity and performance by design
The 8588A incorporates exceptional linearity, low noise and stability in the design. This best-in-class long-scale digital reference multimeter guarantees superior 3.5 ppm one-year dc voltage relative accuracy and long-term stability over a wide measurement range and functions.
The 8588A contains the world’s most stable voltage references and attenuators custom crafted at Fluke Calibration. These precision components eliminate the need for daily internal self-calibration to compensate for drift when less-precise components are used. Autozeroing also becomes unnecessary because the amplifier offsets are ultra-stable. The 8588A achieves an exceptional 8.5-digit resolution reading in one second, two times shorter than the next best in class, which amounts to considerable productivity improvements.
The 8588A is easy and intuitive to use. It is the ideal lab multimeter for metrologists and calibration laboratory managers who expect and appreciate a straightforward setup that quickly achieves the maximum performance of the instrument.
- 2.7 µV/V (95%), 3.5 µV/V (99%), 1 year relative accuracy, dc voltage without internal self-calibration or auto-adjustments
- 0.5 µV/V (95%), 0.65 µV/V (99%), 24 hour stability, dc voltage
- 7 µΩ/Ω (95%), 9 µΩ/Ω (99%), 1 year, resistance
- 2.02x full scale stretches lower noise floor to higher signal levels to maximize higher accuracies from the instrument
- 200 ns to 100 s aperture setting allows the industry's widest flexibility to control data capture window
Accuracy, offset and stability provide excellent ac performance
The 8588A provides the most accurate true ac rms measurement available in a Fluke Calibration multimeter.
With a 5 mega-samples-per-second sampling analog-to-digital converter and an extraordinarily stable dc analog path, the 8588A achieves remarkable ac rms measurement performance that is ten times faster, two times less noisy, and more sensitive for low level signals than other instruments in this class. It utilizes digital rms calculations to maintain full resolution of a wide dynamic range of digitized signals, so you can see a wide range of measurements clearly.
Rapid digital filters are more effective than their analog equivalents for faster settling. The digital filters eliminate the dielectric absorption on analog filters, commonly associated with residual slow-tail characteristics. The digital filters effectively shorten settling time to within 6 cycles of the filter frequency and less than 1 ppm of the fully settled value.This is up to 10 times faster than other long scale precision digital multimeters at low frequencies.
Low noise is achieved from averaging the collected high-resolution digitized data and the inherently stable signal path. De-coupling low level signal sensitivity from temperature drift enables the 8588A to make higher accuracy low-level ac measurements. Therefore, temperature drift, offsets, and long-term instability typically associated with an analog rms converter are eliminated.
- 60 µV/V (95%), 77 µV/V (99%), 1 year relative accuracy, for the most accurate ac voltage measurement
- 250 µA/A (95%), 323 µA/A (99%), 1 year relative accuracy, ac current
- 15 ms settling time at 1kHz ac filter form 10x faster ac voltage measurement
- 2.02x full scale Vpp, 1.2x full scale rms
- Up to 30 A for peak ac current greatly extends ac current measurement range
Key feature and specification comparison
8588A | 8558A | |
---|---|---|
DC voltage | 100 mV – 1000 V | 100 mV – 1000 V |
AC voltage | 10 mV – 1000 V, 1 Hz – 10 MHz | 10 mV – 1000 V, 1 Hz – 10 MHz |
Resistance, LoI, HV | 1 Ω - 10 GΩ | 1 Ω - 10 GΩ |
DC current | 10 uA – 30 A | 10 uA – 2 A |
AC current | 10 uA – 30 A, 1 Hz to 100 kHz | 10 uA – 2A, 1 Hz to 100 kHz |
Digitize V |
100 mV - 1000 V, 5 MSamples/s, up to 20
MHz BW
|
100 mV - 1000 V, 5 MSamples/s, up to 20
MHz BW
|
Digitize I |
10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW
|
10 uA - 2 A, 5 MSamples/s,
up to 4 MHz BW
|
Frequency (V, I, BNC) | 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz | 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz |
Temperature | PRT / Thermocouple (ext CJC) | PRT / Thermocouple (ext CJC) |
Capacitance | 1 nF – 100 mF | No |
RF power | R&S NRP Series | No |
Ext. dc current and ac current | A40B current shunt and other shunts | No |
Graphical display | Yes | Yes |
Visual Connection Management ® | Yes | Yes |
Programmable front/rear input switching | Yes | Yes |
Ratio difference, deviation - ohms, voltage, current | Yes | Yes |
External 10 MHz ref clock, 50 Ω/Hi-Z | Yes | Yes |
A40B and other shunt asset management | Yes | No |
GPIB 488.2, Ethernet, USB TMC | Yes | Yes |
SCPI command compatibility | Yes | Yes |
3458A emulation, 8508A emulation | Yes | Yes |
Volatile memory | 15 million | 15 million |
Level and other trigger | Yes | Yes |
FFT onboard | Yes | No |
Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits | Yes | Yes |
Function | 8588A uX/X of reading + uX/X of range | 8558A uX/X of reading + uX/X of range | ||||
---|---|---|---|---|---|---|
95% | 99% | 95% | 99% | |||
DC voltage | 10 V | relative | 2.7 + 0.05 | 3.5 + 0.06 | 4.0 + 0.06 | 5.2 + 0.08 |
absolute | 2.8 + 0.05 | 3.6 + 0.06 | 4.1 + 0.06 | 5.3 + 0.08 | ||
AC voltage | 10 V, 1 kHz | relative | 60 + 5 | 77 + 6.5 | 80 + 10 | 103 + 13 |
absolute | 64 + 5 | 83 + 6.5 | 90 + 10 | 116 + 13 | ||
Resistance | 10 kΩ | relative | 7 + 0.5 | 9 + 0.6 | 10 + 0.6 | 13 + 0.7 |
absolute | 7.2 + 0.5 | 9.2 + 0.6 | 10.3 + 0.6 | 13.3 + 0.7 | ||
DC current | 1 mA | relative | 6.5 + 4 | 8.4 + 5 | 9 + 5 | 12 + 6 |
absolute | 7.6 + 4 | 10 + 5 | 9.8 + 5 | 13 + 6 | ||
AC current | 1 mA, 1 kHz | relative | 250 + 50 | 323 + 65 | 300 + 100 | 387 + 129 |
absolute | 260 + 50 | 335 + 65 | 310 + 100 | 400 + 129 | ||
Frequency | BNC,1 kHz | relative | 0.5 uHz/Hz | 0.5 uHz/Hz | 0.5 uHz/Hz | 0.5 uHz/Hz |
Temperature | PRT 100 Ω | relative | ± 5 mK | ± 5 mK | ± 5 mK | ± 5 mK |
Capacitance | 1 uF | relative | 400 + 100 | 516 + 129 | N/A | N/A |
absolute | 406 + 100 | 523 + 129 | N/A | N/A |
95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2).
Looking for lower specs? See our other benchtop multimeters:
Bench Multimeter Selection Guide | |||
---|---|---|---|
Model | Resolution | Accuracy | Application |
8588A | 8.5 | 2.7 µV/V 95% confidence level, 1 year relative accuracy | Metrology |
8558A | 8.5 | 4.0 µV/V 95% confidence level, 1 year relative accuracy | High-Speed Automation |
8845A/8846A | 6.5 | Basic V dc accuracy of up to 0.0024 % | Bench |
8808A | 5.5 | Basic V dc accuracy of 0.015 % | Bench |