Fluke Calibration 8588A Reference Multimeter

  • ₦0.00
  • Fluke Calibration 8588A Reference MultimeterStability, simplicity and performance by design The 8588A incorporates exceptional linearity, low noise and stability in the design. This best-in-class long-scale digital reference multimeter guarantees superior 3.5 ppm one-year dc voltage relative accuracy and long-term stability over a wide measurement range and functions. The 8588A contains...



    Add to quote

    Fluke Calibration 8588A Reference Multimeter

    Stability, simplicity and performance by design

    The 8588A incorporates exceptional linearity, low noise and stability in the design. This best-in-class long-scale digital reference multimeter guarantees superior 3.5 ppm one-year dc voltage relative accuracy and long-term stability over a wide measurement range and functions.

    The 8588A contains the world’s most stable voltage references and attenuators custom crafted at Fluke Calibration.  These precision components eliminate the need for daily internal self-calibration to compensate for drift when less-precise components are used.  Autozeroing also becomes unnecessary because the amplifier offsets are ultra-stable.  The 8588A achieves an exceptional 8.5-digit resolution reading in one second, two times shorter than the next best in class, which amounts to considerable productivity improvements.

    The 8588A is easy and intuitive to use. It is the ideal lab multimeter for metrologists and calibration laboratory managers who expect and appreciate a straightforward setup that quickly achieves the maximum performance of the instrument.

    • 2.7 µV/V (95%), 3.5 µV/V (99%), 1 year relative accuracy, dc voltage without internal self-calibration or auto-adjustments
    • 0.5 µV/V (95%), 0.65 µV/V (99%), 24 hour stability, dc voltage
    • 7 µΩ/Ω (95%), 9 µΩ/Ω (99%), 1 year, resistance
    • 2.02x full scale stretches lower noise floor to higher signal levels to maximize higher accuracies from the instrument
    • 200 ns to 100 s aperture setting allows the industry's widest flexibility to control data capture window

    Accuracy, offset and stability provide excellent ac performance

    The 8588A provides the most accurate true ac rms measurement available in a Fluke Calibration multimeter.

    With a 5 mega-samples-per-second sampling analog-to-digital converter and an extraordinarily stable dc analog path, the 8588A achieves remarkable ac rms measurement performance that is ten times faster, two times less noisy, and more sensitive for low level signals than other instruments in this class. It utilizes digital rms calculations to maintain full resolution of a wide dynamic range of digitized signals, so you can see a wide range of measurements clearly.

    Rapid digital filters are more effective than their analog equivalents for faster settling. The digital filters eliminate the dielectric absorption on analog filters, commonly associated with residual slow-tail characteristics. The digital filters effectively shorten settling time to within 6 cycles of the filter frequency and less than 1 ppm of the fully settled value.This is up to 10 times faster than other long scale precision digital multimeters at low frequencies.

    Low noise is achieved from averaging the collected high-resolution digitized data and the inherently stable signal path. De-coupling low level signal sensitivity from temperature drift enables the 8588A to make higher accuracy low-level ac measurements. Therefore, temperature drift, offsets, and long-term instability typically associated with an analog rms converter are eliminated.

    • 60 µV/V (95%), 77 µV/V (99%), 1 year relative accuracy, for the most accurate ac voltage measurement
    • 250 µA/A (95%), 323 µA/A (99%), 1 year relative accuracy, ac current
    • 15 ms settling time at 1kHz ac filter form 10x faster ac voltage measurement
    • 2.02x full scale Vpp, 1.2x full scale rms
    • Up to 30 A for peak ac current greatly extends ac current measurement range

     

    Key feature and specification comparison

      8588A 8558A
    DC voltage 100 mV – 1000 V 100 mV – 1000 V
    AC voltage 10 mV – 1000 V, 1 Hz – 10 MHz 10 mV – 1000 V, 1 Hz – 10 MHz
    Resistance, LoI, HV 1 Ω - 10 GΩ 1 Ω - 10 GΩ
    DC current 10 uA – 30 A 10 uA – 2 A
    AC current 10 uA – 30 A, 1 Hz to 100 kHz 10 uA – 2A, 1 Hz to 100 kHz
    Digitize V
    100 mV - 1000 V, 5 MSamples/s, up to 20
    MHz BW
    100 mV - 1000 V, 5 MSamples/s, up to 20
    MHz BW
    Digitize I
    10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW
    10 uA - 2 A, 5 MSamples/s,
    up to 4 MHz BW
    Frequency (V, I, BNC) 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz
    Temperature PRT / Thermocouple (ext CJC) PRT / Thermocouple (ext CJC)
    Capacitance 1 nF – 100 mF No
    RF power R&S NRP Series No
    Ext. dc current and ac current A40B current shunt and other shunts No
    Graphical display Yes Yes
    Visual Connection Management ® Yes Yes
    Programmable front/rear input switching Yes Yes
    Ratio difference, deviation -  ohms, voltage, current Yes Yes
    External 10 MHz ref clock, 50 Ω/Hi-Z Yes Yes
    A40B and other shunt asset management Yes No
    GPIB 488.2, Ethernet, USB TMC Yes Yes
    SCPI command compatibility Yes Yes
    3458A emulation, 8508A emulation Yes Yes
    Volatile memory 15 million 15 million
    Level and other trigger Yes Yes
    FFT onboard Yes No
    Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits Yes Yes

     

    Function     8588A uX/X of reading + uX/X of range  8558A uX/X of reading + uX/X of range 
          95% 99% 95% 99%
    DC voltage 10 V relative 2.7 + 0.05 3.5 + 0.06 4.0 + 0.06 5.2 + 0.08
    absolute 2.8 + 0.05 3.6 + 0.06 4.1 + 0.06 5.3 + 0.08
    AC voltage 10 V, 1 kHz relative 60 + 5 77 + 6.5 80 + 10 103 + 13
    absolute 64 + 5 83 + 6.5 90 + 10 116 + 13
    Resistance 10 kΩ relative 7 + 0.5 9 + 0.6 10 + 0.6 13 + 0.7
    absolute 7.2 + 0.5 9.2 + 0.6 10.3 + 0.6 13.3 + 0.7
    DC current 1 mA relative 6.5 + 4 8.4 + 5 9 + 5 12 + 6
    absolute 7.6 + 4 10 + 5 9.8 + 5 13 + 6
    AC current 1 mA, 1 kHz relative 250 + 50 323 + 65 300 + 100 387 + 129
    absolute 260 + 50 335 + 65 310 + 100 400 + 129
    Frequency BNC,1 kHz relative 0.5 uHz/Hz 0.5 uHz/Hz 0.5 uHz/Hz 0.5 uHz/Hz
    Temperature PRT 100 Ω relative ± 5 mK ± 5 mK ± 5 mK ± 5 mK
    Capacitance 1 uF relative 400 + 100 516 + 129 N/A N/A
    absolute 406 + 100 523 + 129 N/A N/A

    95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2).

    Looking for lower specs? See our other benchtop multimeters:

    Bench Multimeter Selection Guide
    Model Resolution Accuracy Application
    8588A 8.5 2.7 µV/V 95% confidence level, 1 year relative accuracy Metrology
    8558A 8.5 4.0 µV/V 95% confidence level, 1 year relative accuracy High-Speed Automation
    8845A/8846A 6.5 Basic V dc accuracy of up to 0.0024 % Bench
    8808A 5.5 Basic V dc accuracy of 0.015 % Bench