Fluke 375 600A TRMS Clampmeter

    • SKU: Fluke-375
    • Brand: Fluke
    • Availability: In Stock

    Fluke 375 600A TRMS ClampmeterPowerpro company Limited is the distributor, supplier and service provider of ( Test Equipment Product Sales, Test Equipment Calibration, Test Equipment Rentals and Product Training) in Nigeria. Product overview: Fluke 375 True RMS AC/DC Clamp Meter Be ready for anything. With True RMS AC voltage and...



    Add to quote

    Fluke 375 600A TRMS Clampmeter

    Powerpro company Limited is the distributor, supplier and service provider of ( Test Equipment Product Sales, Test Equipment Calibration, Test Equipment Rentals and Product Training) in Nigeria.

    Product overview: Fluke 375 True RMS AC/DC Clamp Meter

    Be ready for anything.

    With True RMS AC voltage and current measurements, the Fluke 375 Clamp Meter can read up to 600 V and 600 A in both AC and DC modes, and is capable of frequency measurement up to 500 Hz. Additionally, the 375 is compatible with the new iFlex flexible current probe (sold separately), which expands the measurement range to 2500 A AC.

     

    Key features

    • iFlex flexible current probe expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
    • CAT IV 600 V, CAT III 1000 V
    • True RMS AC voltage and current for accurate measurements on non-linear signals
    • 500 mV DC measurement range to interface with other accessories
    • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
    • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
    • Ergonomic design fits in your hand and can be used while wearing protective equipment
    • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
    • Three-year warranty
    • Soft carrying case

    Specifications: Fluke 375 True RMS AC/DC Clamp Meter

    Electrical Specifications
    AC Current via Jaw
    Range 374 and 375
    376
    600.0 A
    999.9 A
    Resolution 0.1 A
    Accuracy 2% ± 5 digits (10-100 Hz)
    2.5% ± 5 digits (100-500 Hz)
    Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
    2.5 @ 600 A
    1.42 @1000 A (376 only)
    Add 2% for C.F. > 2
    AC Current via Flexible Current Probe
    Range 2500 A
    Resolution 374 and 375 0.1 A (≤ 600 A)
    1 A (≤ 2500 A)
    376 0.1 A (≤ 999.9 A)
    1 A (≤ 2500 A)
    Accuracy 3% ±5 digits (5 – 500 Hz)
    Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
    2.5 at 1400 A
    1.42 at 2500 A
    Add 2% for C.F. > 2
    Distance from Optimum i2500-10 Flex i2500-18 Flex Error
    Flexible current probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
    B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
    C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
    Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    DC Current
    Range 374 and 375
    376
    600.0 A
    999.9 A
    Resolution 0.1 A
    Accuracy 2% ± 5 digits
    AC Voltage
    Range 374 and 375
    376
    600.0 V
    1000 V
    Resolution 374 and 375
    376
    0.1 V
    0.1 V (≤ 600.0 V)
    1 V (≤ 1000 V)
    Accuracy 1.5% ± 5 digits (20 – 500 Hz)
    DC Voltage
    Range 374 and 375
    376
    600.0 V
    1000 V
    Resolution 374 and 375
    376
    0.1 V
    0.1 V (≤ 600.0 V)
    1 V (≤ 1000 V)
    Accuracy 1% ± 5 digits
    mV dc
    Range 375 and 376 500.0 mV
    Resolution 0.1 mV
    Accuracy 1% ± 5 digits
    Frequency via Jaw
    Range 375 and 376 5.0 - 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5% ± 5 digits
    Trigger Level 5 – 10 Hz, ≥10 A
    10 – 100 Hz, ≥5 A
    100 – 500 Hz, ≥10 A
    Frequency via Flexible Current Probe
    Range 375 and 376 5.0 - 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5% ± 5 digits
    Trigger Level 5 – 20 Hz, ≥ 25 A
    20 – 100 Hz, ≥ 20 A
    100 – 500 Hz, ≥ 25 A
    Resistance
    Range 374
    375 and 376
    6000 Ω
    60 kΩ
    Resolution 374 0.1 Ω (≤ 600 Ω)
    1 Ω (≤ 6000 Ω)
    375 and 376 0.1 Ω (≤ 600 Ω)
    1 Ω (≤ 6000 Ω)
    10 Ω (≤ 60 kΩ)
    Accuracy 1% ± 5 digits
    Capacitance
    Range 1000 μF
    Resolution 0.1 μF (≤ 100 μF)
    1 μ F (≤ 1000 μF)
    Accuracy 1% ± 4 digits
    Mechanical Specifications
    Size (L x W x H) 246 mm x 83 m x 43 mm
    Weight 388 g
    Jaw Opening 34 mm
    Flexible Current Probe Diameter 7.5 mm
    Flexible Current Probe Cable Length
    (head to electronics connector)
    1.8 m
    Environmental Specifications
    Operating Temperature 10°C – +50°C
    Storage Temp -40°C – +60°C
    Operating Humidity Non condensing (< 10 –°C)
    ≤ 90% RH (at 10°C – 30°C)
    ≤ 75% RH (at 30°C – 40°C)
    ≤ 45% RH (at 40°C – 50°C)
    Operating Altitude 3000 meters
    Storage Altitude 12,000 meters
    EMC EN 61326-1:2006
    Temperature Coefficients Add 0.1 x specified accuracy for each
    degree C above 28°C or below 18°C
    Safety Specifications
    Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
    ANSI/UL 61010-1:2004
    ANSI/ISA-61010-1 (82.02.01):2004
    EN/IEC 61010-1:2001 to
    1000V Measurement Category (CAT) III
    600V Measurement Category (CAT) IV
    Pollution Degree 2
    EN/IEC 61010-2-032:2002
    EN/IEC 61010-031:2002+A1:2008
    Agency Approvals
    Batteries 2 AA, NEDA 15A, IEC LR6