Fluke Calibration 2271A Industrial Pressure Calibrator

  • Fluke Calibration 2271A Industrial Pressure CalibratorWide workload coverage for the present and the future The 2271A features pressure ranges from -100 kPa to 20 MPa (-15 to 3000 psi), which covers the requirements of a wide range of gauges and sensors. Thanks to its modular design, the 2271A enables you...



    Add to quote

    Fluke Calibration 2271A Industrial Pressure Calibrator

    Wide workload coverage for the present and the future

    The 2271A features pressure ranges from -100 kPa to 20 MPa (-15 to 3000 psi), which covers the requirements of a wide range of gauges and sensors. Thanks to its modular design, the 2271A enables you to install two modules with different measurement ranges within the same chassis. You can purchase modules to match your current workload now; later, when your workload changes and grows, you can easily add ranges, swapping modules in and out according to your workload. This flexibility enables you to maintain your investment in the 2271A for years to come.

    A built-in electrical measurement module (EMM) with HART capabilities enables you to perform closed loop, fully automated calibration on 4-20 mA devices such as smart transmitters, gauges and switches. Just set up the 2271A and then walk away to attend to other tasks.

    The EMM supplies 24 V dc loop power for measuring mA and V dc. It has a built-in 250 Ohm resistor that can be toggled on or off, eliminating the need to have an external resistor to enable HART communications.

    The 2271A accuracy specifications are provided in full and supported by a Technical Note that details its measurement uncertainty, so you know exactly what you are getting. The Technical Note is available for download on the flukecal.com website. As with all Fluke Calibration instruments, these specifications are conservative, complete and dependable.

    Versatile pressure measurement modules

    The 2271A uses PM200 and PM500 Pressure Measurement Modules that let you set up a system that matches your needs for accuracy and value:

    Good: PM200 Pressure Measurement Modules Better: PM500 Pressure Measurement Modules
    • 0.02% FS specification makes it ideal for calibrating or testing pressure dial gauges, lower accuracy transmitters, or pressure switches
    • Rugged silicon pressure sensor design allows for faster control
    • Economic price point helps facilitate the purchase of backup modules, making sure you are never down for calibration
    • Highly characterized and linearized silicon pressure sensor provides an economical way of making accurate pressure measurements
    • 0.01 reading measurement uncertainty from 50% to 100% for most ranges allows for wide workload coverage
    • More than 45 ranges, from low differential pressures up to 20 MPa (3000 psi) to choose from. Your application is covered with this wide flexibility in configuration.

    Install up to two pressure modules in the 2271A chassis at one time, mixing and matching module classes and ranges to get the combination that best suits your needs. There is no limit to the number of modules that can be used with the system, allowing you to change pressure ranges on the fly to meet your needs. Modules snap in and out quickly and easily through the front of the 2271A; just slide each into a specially-designed track and tighten the knob until you hear it click into place. The click tells you the module is safely in place; a special anti-torque guard on the knob prevents over-tightening so you never have to wonder if you tightened it too much or not enough.

    Each module uses an enhanced face-seal design that has been leak tested to pressures three times higher than the maximum working pressure. You don’t have to worry about a leak in the system affecting your ability to measure and control pressure.

     

    General specifications
    Mains
    Power requirements 100 V ac to 240 V ac, 47 Hz to 63 Hz
    Fuse T2A 250 V ac
    Max power consumption 100 W
    Environment
    Operating Ambient Temperature Range 15 °C to 35 °C
    Storage temperature -20 °C to 70 °C
    Relative Humidity Operating: <80 % to 30 °C, <70 % to 35 °C Storage: <95 %, non-condensing. A power stabilization period of four days may be required after extended storage at high temperature and humidity.
    Vibration MIL-T-28800D CLASS 3
    Altitude (Operation) <2000 m
    Warmup time 15 minutes after power up or module installation, when items previously stored within operating ambient temperature
    Electromagnetic compatibility (EMC)
    International IEC 61326-1: Controlled Electromagnetic Environment
      Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
    Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Compliance
    Ingress protection IEC 60529: IP20
    Safety IEC 61010-1, Installation Category II, Pollution degree 2
    Dimensions and weights
    Dimensions
    Height 2271A-NPT-STD 305 mm (12 in)
    2271A-BSP-STD 305 mm (12 in)
    2271A-NPT-P3000 237 mm (9.33 in)
    2271A-BSP-P3000 237 mm (9.33 in)
    Width 442 mm (17.40 in)
    Depth 446 mm (17.55 in)
    Weight
    Chassis only 15 kg (33.06 lbs)
    Communication interfaces
    Primary remote interfaces Ethernet, RS232, USB
    Electrical Measurement Module (EMM)
    Connection
    Banana jack
    Maximum 30 V dc w.r.t. chassis ground
    Aux drivers 4 external Solenoid Drivers
    24 V dc. 100 % duty cycle when turned, reducing to 40 % shortly after.

    You can use this tab for adding shipping details, return policies and information or measurements etc.