    Baur/HVT 411+067 - PD-TaD 62 PD Diagnostics SystemThe PD-TaD 62 portable PD diagnostics system is used in combination with a BAUR VLF generator for carrying out: Partial discharge testing and location VLF cable testing with parallel partial discharge testing Parallel partial discharge and dissipation factor measurement Full MWT With the...



    Add to quote

    Baur/HVT 411+067 - PD-TaD 62 PD Diagnostics System

    The PD-TaD 62 portable PD diagnostics system is used in combination with a BAUR VLF generator for carrying out:

    • Partial discharge testing and location
    • VLF cable testing with parallel partial discharge testing
    • Parallel partial discharge and dissipation factor measurement
    • Full MWT

    With the partial discharge testing and the dissipation factor measurement, two effective and proven methods for evaluating the aging condition of medium-voltage cables and cable accessories have been combined in a single compact and portable device. The result is a one-step 360° cable analysis with early detection and localization of weak points through a PD measurement, in addition to the evaluation of dielectric aging based on the dissipation factor values.

    The ability to perform partial discharge and dissipation factor measurements simultaneously saves a lot of time and leads to increased efficiency during inspection of the entire cable network. The simultaneous monitoring of tan δ values and PD activities, also helps detect hidden faults (e.g. moist joints).

    Light, robust and portable: PD-TaD is ideal for mobile use in the field. The device and accessories are convenient to transport in robust transport cases.

    Combination of methods for more significant information

    With the BAUR PD-TaD 62, in combination with a BAUR VLF generator with tan δ measurement function, dielectric losses can be measured and the cable route can be tested for partial discharges during the VLF cable test. This combination of methods is called Full MWT and provides significantly more information than the cable test alone. While the cable test shows whether the cable system can withstand a load over a specified test duration, the dissipation factor measurement enables an evaluation of the condition of the cable insulation. Moreover, partial discharge testing shows and locates the PD faults precisely. The highlight of MWT is the condition-based test duration: Provided it is permitted, the test duration can be shortened, which in turn lowers costs. This way, the cable is only exposed to the increased test voltage for the required duration.
     

    Combination of methods for more significant information
    VLF truesinus® – A voltage shape for all methods and method combinations

    VLF truesinus® is the only voltage shape that enables both reliable voltage tests as well as precise dissipation factor measurement and partial discharge testing. Unlike other voltage shapes, the VLF truesinus® voltage is load-independent, symmetrical, and continuous. This is a prerequisite for high precision as well as reproducibility and comparability of measurement results.
     

    Available methods and combinations of methods with PD-TaD 62
    Method Significance and benefits BAUR mobile equipment*
    PD testing
    • Diagnostics of local weak points
    • Location of faults in the cable insulation
    PD-TaD 62 &
    frida / viola
    VLF cable testing with parallel PD testing
    • Intelligent withstand voltage test
    • Diagnostics of local weak points
    • Location of faults in the cable insulation
    PD-TaD 62 &
    frida / viola
    Dissipation factor measurement
    • Evaluation of the dielectric condition of the insulation
    • Indication of PD, water trees, humidity in joints, etc.
    PD-TaD 62 &
    frida TD / viola TD
    Simultaneous tan δ measurement and PD testing
    • Combination of statements of a tan δ measurement and PD testing
    • Shorter test duration with simultaneous tan δ measurement and PD testing
    • Better detection of hidden faults (e.g. moist joints) and simultaneous analysis of tan δ values and PD activities
    PD-TaD 62 &
    frida TD / viola TD
    Full MWT
    • Combination of statements of a tan δ measurement and PD testing
    • Shorter test duration with simultaneous tan δ measurement and PD testing
    • Intelligent withstand voltage test with shorter test duration for cables in good condition