{"product_id":"fluke-networks-fqm-100-m-vfl-fiber-quickmap-kit-with-visifault","title":"Fluke Networks FQM-100-M-VFL Fiber QuickMap Kit with VisiFault","description":"\u003ch3 class=\"highlight-heading product-section-heading expand-description\"\u003eManufacturer Specs \u003ci class=\"fa fa-sm fa-chevron-down float-right text-secondary\"\u003e\u003c\/i\u003e\n\u003c\/h3\u003e\u003cdiv class=\"hidden hidden-description\"\u003e\u003cdiv class=\"table-responsive\"\u003e\n\n\u003ccenter\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"spectable\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellheader\" colspan=\"2\"\u003eFluke Networks Fiber QuickMap Series Specifications\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eOperating temperature with the battery\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e0ºC to 50ºC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eNon-operating temperature\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e-20ºC to 60ºC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eOperating relative humidity (without condensation)\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e95% (10ºC to 35ºC) 75% (35ºC to 40ºC) uncontrolled \u0026lt; 10ºC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eVibration\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eRandom, 5 Hz to 500 Hz, MIL-PRF-28800F CLASS 2\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eShock\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e1 meter drop test\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eAltitude\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e3000m\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eEMC\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eEN 61326-1: 2004\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eBattery type\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e2 AA alkaline batteries (no battery charger)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eBattery life\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e1500 tests (typical)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eLaser safety\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eClass 1 CDRH Complies to EN 60825-2\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eLCD type\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eBacklit black and white (segments)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eIndex of refraction range\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e1.45 to 1.5 (factory default is 1.496)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eAuto turn off\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eAutomatically turns off after 5 minutes if no keys are pressed. Backlight turns off first.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eFactory calibration interval\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eNone\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eOutput wavelengths\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e850 nm ± 10 nm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eLaser classification\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eClass 1 CDRH Complies to EN 60825-2\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eDynamic range\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e\u0026gt;11 dB\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eMaximum distance\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e1500 meters or 4921 feet\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eMaximum number of incidents shown\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e9\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eDistance accuracy (0 m to 1500 m or 0 ft to 4921 ft)\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e± (1 m + 0.1 % x length) for reflective incidents1 ± (3 m + 0.1 % x length) for non-reflective incidents\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eTesting speed\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e\u0026lt; 6 seconds typical\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eConnector\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eRemovable\/cleanable SC adapter, UPC polish\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eFiber types tested\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e50\/125 µm or 62.5\/125 µm multimode\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eDetection of reflective incidents\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e-35 dB default threshold (User selectable: -20 dB to -45 dB in 5 dB increments)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eReflectance accuracy\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e± 4 dB\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eMaximum reflectance measurement\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e-20 dB\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eDetection of loss incidents\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e0.70 dB default threshold (user-configurable from 0.5 dB to 6.1 dB in 0.2 dB increments)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eBulkhead quality\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eIf no fiber is attached or if the connector is dirty, the troubleshooter displays 0 m or 0 ft.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eLive fiber detection\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eDetects optical signals from 600 nm to 1050 nm and shows ACTIVE LINE if a signal is there. Looks for a signal every 3 seconds after the first detection. +7 dB maximum input power.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eCertifications and compliance\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eConforms to relevant European Union directives\u003cbr\u003e\n\t\t\tConforms to relevant Australian standards\u003cbr\u003e\n\t\t\tListed by the Canadian Standards Association CSA C22.2 No. 61010.1.04\u003cbr\u003e\n\t\t\tConforms to FCC Rules, Part A, Class A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\n\t\t\t\u003col\u003e\n\t\t\t\t\u003cli\u003e± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for reflective incidents: ±1 m from 1 m to 1.5 km.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for non-reflective incidents: ±2 m for lengths £15 m, otherwise ±1 m.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFinds and gives the location of an incident that has a reflectance larger than -55 dB. Detects incidents \u0026gt;1m after the bulkhead connector when the bulkhead reflectance is \u0026lt;35 dB. Detects incidents \u0026gt;3 m after an incident when the incident reflectance is \u0026lt;35 dB.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eWith a backscatter coefficient of -63 dB at 850 nm using a calibrated -14 dB reference.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetects incidents \u0026gt;10 m after the bulkhead connector or any prior incident when the bulkhead reflectance is \u0026lt;-35 dB and the reflectance of any prior incident is \u0026lt;-35 dB. The maximum link loss prior to the incident is \u0026lt;7 dB.\u003c\/li\u003e\n\t\t\t\u003c\/ol\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/center\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":48345677332669,"sku":"FQM-100-M-VFL","price":5899500.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/files\/Fiber_QuickMap_Series-g.jpg?v=1787958334","url":"https:\/\/www.powerpro.ng\/products\/fluke-networks-fqm-100-m-vfl-fiber-quickmap-kit-with-visifault","provider":"Powerpro Company Limited","version":"1.0","type":"link"}