{"product_id":"fluke-networks-dsx-add-1-ghz-dsx-cable-analyzer-modules-add-on-kit","title":"Fluke Networks DSX-ADD 1 GHz DSX Cable Analyzer Modules Add-on Kit","description":"\u003cscript type=\"text\/javascript\"\u003e\n       jQuery(function ($) {\n           var data = { \"F\": \"GetRandomBanner\", \"AjaxBannerGroupId\": \"0\", \"BannerGroupId\": \"522\", \"RawUrl\": \"\/Fluke-Networks\/DSX-ADD\/Datacom-Cable-Testers\/\" };\n            LoadControl(data, '#ctrlBannerContainer');\n        });\n    \u003c\/script\u003e\n\n\n\u003cdiv id=\"ctrlBannerContainer\"\u003e\u003c\/div\u003e\n\n\n    \u003chr\u003e\n    \u003cp id=\"short-description\" class=\"py-0\"\u003e\n        \u003csmall\u003e1 GHZ DSX CABLE ANALYZER MODULES ADD ON KIT\u003c\/small\u003e\n    \u003c\/p\u003e\n\n\n\n\n\n\u003cstyle\u003e\n.haz-gridwrapper {\n  -webkit-box-flex: 1;\n    flex-grow: 1;\n    width: 100%;\n    margin: 0px auto;\n    background: rgb(247, 249, 250);\n    padding: .5rem !important;\n    margin-bottom: 20px;\n}\n\n.haz-gridoffset {\n    display: flex;\n    flex-wrap: wrap;\n    width: calc(100% + 10px);\n}\n\n.haz-griditem {\n    box-sizing: border-box;\n    margin: 0px;\n    -webkit-box-flex: 0;\n    flex-grow: 0;\n    flex-shrink: 1;\n    overflow: visible;\n    display: flex;\n    flex-direction: row;\n    padding: 5px;\n    align-items: flex-start;\n    overflow-wrap: break-word;\n    word-break: break-word;\n    flex-basis: 50%;\n    max-width: 50%;\n    font-size: .87rem;\n    white-space: nowrap;\n    letter-spacing: -0.0625rem;\n}\n\n.haz-svg {\n    display: flex;\n    margin-right: 0.4rem !important;\n    margin: 0px;\n    padding: 0px;\n    font-size: inherit;\n    font-weight: inherit;\n}\n\n.haz-desc {\n  flex-basis: 100% !important;\n  max-width: 100% !important;\n  white-space: normal !important;      \/* override the nowrap *\/\n}\n\n\/* prevent the URL itself from breaking *\/\n.haz-desc a {\n  white-space: nowrap;\n  word-break: normal;\n}\n\n\u003c\/style\u003e\n\n\n\n\u003cdiv id=\"divFeature\" class=\"itemDesc more itemFeatures\"\u003e\n\t\n    \u003cul\u003e\n\t\u003cli\u003e\u003cstrong\u003eDSX-ADD Versiv DSX Add Kit\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eVersiv enables users to accomplish more than ever with a cable tester, by accelerating every step of the testing process\u003c\/li\u003e\n\t\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\t\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\t\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\t\u003cli\u003eThe DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple test that locates the problem\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eTen second Cat 6A test time contributes to the fastest way to gain certification\u003c\/li\u003e\n\t\u003cli\u003eGraphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting\u003c\/li\u003e\n\t\u003cli\u003eManage up to 12,000 test results with full graphics\u003c\/li\u003e\n\t\u003cli\u003eCapacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters\u003c\/li\u003e\n\t\u003cli\u003e1 billion links reported on LinkWare management software\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eCompliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz\u003c\/li\u003e\n\t\u003cli\u003eSupports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) – IEC61935-1 \u0026amp; 11801-1-4, IEEE 802.3af, IEEE 802.3at, ANSI\/TIA\/EIA-568-C.2\u003c\/li\u003e\n\t\u003cli\u003eNext generation balance drafts – IEEE 802.3, TIA TR42.7\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"showMore\" style=\"display: none;\"\u003e\n    \u003cimg src=\"\/cms\/images\/down-arrow.png\" alt=\"down-arrow\"\u003e\n    Show More\n\u003c\/div\u003e\n\u003cdiv id=\"showLess\" style=\"display: none;\"\u003e\n    \u003cimg src=\"\/cms\/images\/up-arrow.png\" alt=\"down-arrow\"\u003e\n    Show Less\n\u003c\/div\u003e\n\n\n    \u003ca href=\"#description\" class=\"aViewProductDetails\"\u003e\u003csmall\u003eView Product Details\u003c\/small\u003e\u003c\/a\u003e\n\n\u003cbr\u003e\n\u003cbr\u003e \u003ch3 class=\"highlight-heading product-section-heading expand-description\"\u003eManufacturer Specs \u003ci class=\"fa fa-sm fa-chevron-down float-right text-secondary\"\u003e\u003c\/i\u003e\n\u003c\/h3\u003e\u003cdiv class=\"hidden hidden-description\"\u003e\n\u003ctitle\u003e\u003c\/title\u003e\n\u003clink href=\"http:\/\/www.iwhtech.com\/private\/css\/default.css\" rel=\"stylesheet\" type=\"text\/css\"\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"spectable\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003eCable Types\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eShielded and unshielded pair LAN cabling\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eTIA Category 3, 4, 5, 5e, 6, 6A: 100 ?\u003cbr\u003e\n\t\t\tISO\/IEC Class C, D, E, EA, F, and FA: 100 ? and 120 ?\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003eStandard Link Interface Adapters\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003ePermanent link adapters\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003ePlug type: shielded RJ45\u003cbr\u003e\n\t\t\tOptional Plug type: Tera\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eChannel Adapters\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eJack type: shielded RJ45\u003cbr\u003e\n\t\t\tOptional Jack type: Tera\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003eTest Standards\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eTIA\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eCategory 3, 4, 5, 5e, 6, 6A per TIA 568-C.2\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eISO\/IEC\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eClass C and D, E, EA, F, FA certification per ISO\/IEC 11801:2002 and amendments\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eMaximum frequency\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e1200 MHz\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eSpeed of Autotest\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eFull 2-way Autotest of Category 5e or 6\/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A\/Class EA: 10 seconds\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eSupport test parameters (The selected test standard determines the test parameters and the frequency range of the tests)\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eWire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eInput protection\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eProtected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eDisplay\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e5.7 in LCD display with a projected capacitance touchscreen\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eCase\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eHigh impact plastic with show absorbing overmold\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eDimensions\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eMain Versiv unit with DSX-5000 module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eWeight\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eMain Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eMain unit and remote\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eLithium ion battery pack, 7.2 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eTypical battery life\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e8 hours\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eCharge time\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eTester off: 4 hours to charge from 10 % capacity to 90 % capacity.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eLanguages supported\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eEnglish, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eCalibration\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eService center calibration period is 1 year\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironment Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eOperating Temperature\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e32°F to 113°F (0°C to 45°C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eStorage Temperature\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e-4°F to +122°F (-20° C to +50°C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eOperating relative humidity\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e0 % to 90 %, 32°F to 95 °F (0°C to 35°C)\u003cbr\u003e\n\t\t\t0 % to 70 %, 95°F to 113 °F (35°C to 45°C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eVibration\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eRandom, 2 g, 5 Hz-500 Hz\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eShock\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e1 m drop test with and without module and adapter\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eSafety\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eCSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eOperating altitude\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e13,123 ft (4,000 m)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eEMC\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eEN 61326-1\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003ePerformance Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eCategory 6A\/Class EA test modes (or lower link categories)\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eDSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eClass FA test modes\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eDSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003eDelay Skew\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eRange\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e0 ns to 100 ns\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eResolution\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e1 ns\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eAccuracy\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e± 10 ns\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccellcategory\" colspan=\"2\"\u003e\u003cstrong\u003eDC Loop Resistance Test\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eRange\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e0 ? to 540 ?\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eResolution\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e0.1 ?\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eAccuracy\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003e± (1 ? + 1 %)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd class=\"speccelltitle\" width=\"125\"\u003eOverload recovery time\u003c\/td\u003e\n\t\t\t\u003ctd class=\"speccelldata\"\u003eLess than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":48345684246717,"sku":"DSX-ADD","price":19379250.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/files\/Fluke_DSX-ADD_new.jpg?v=1787958363","url":"https:\/\/www.powerpro.ng\/products\/fluke-networks-dsx-add-1-ghz-dsx-cable-analyzer-modules-add-on-kit","provider":"Powerpro Company Limited","version":"1.0","type":"link"}