{"product_id":"fluke-calibration-9171-field-metrology-well","title":"Fluke Calibration 9171 Field Metrology Well","description":"\u003ch1\u003eFluke Calibration 9171 Field Metrology Well\u003c\/h1\u003e\u003cp\u003eFluke Calibration 9171 Field Metrology Well\u003c\/p\u003e\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke Calibration 9171 Field Metrology Well\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAccurate enough for lab use, and rugged and portable enough to take anywhere\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBest-performing industrial heat sources (accuracy, stability, uniformity) in the world\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eImmersion depth to 203 mm (8 in)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOptional ITS-90 reference input reads PRTs to ±0.006 °C\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature range from –45 °C to 700 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eEvery once in a while, a new product comes around that changes the rules. It happened when we introduced handheld dry-wells. It happened when we introduced Micro-Baths. Now we’ve combined bath-level performance with dry-well functionality and legitimate reference thermometry to create Metrology Wells.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith groundbreaking new proprietary electronics from Fluke Calibration's (patents pending), Metrology Wells let you bring lab-quality performance into whatever field environment you might work in. New analog and digital control techniques provide stability as good as ±0.005 °C. And with dual-zone control, axial (or “vertical”) uniformity is as good as ±0.02 °C over a 60 mm (2.36 in) zone. (That’s 60 mm!) Such performance doesn’t exist anywhere else outside of fluid baths.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIn short, there are six critical components of performance in an industrial heat source (which the European metrology community explains, for example, in the document EA-10\/13): calibrated display accuracy, stability, axial (vertical) uniformity, radial (well-to-well) uniformity, impact from loading, and hysteresis. We added a seventh in the form of a legitimate reference thermometer input and created an entirely new product category: Metrology Wells.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e(By the way, Metrology Wells are the only products on the market supported by published specifications addressing every performance category in the EA-10\/13. Our specs aren’t just hopes or guidelines. They apply to every Metrology Well we sell.)\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke Calibration 9171 Field Metrology Well\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (at 23°C ambient)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–30°C to 155°C (–22°F to 311°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.1°C full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.005°C full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAxial uniformity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.025°C at –30°C\u003cbr\u003e±0.02°C at 0°C ±0.07°C at 155°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadial uniformity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.01°C full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading effect (with a 6.35 mm reference probe and three 6.35 mm probes)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.005°C at –30°C\u003cbr\u003e±0.005°C at 0°C\u003cbr\u003e±0.01°C at 155°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.025°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell depth\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e203 mm (8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.001°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLCD, °C or °F, user-selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey pad\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTen key with decimal and ± button. Function keys, menu key, and °C \/ °F key.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 min: 23°C to –30°C\u003cbr\u003e25 min: 155°C to 23°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e44 min: 23°C to 155°C\u003cbr\u003e56 min: –30°C to 155°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e366 x 203 x 323 mm (14.4 x 8 x 12.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 kg (33 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e115 V AC (±10%), or\u003cbr\u003e230 V AC (±10%), 50\/60 Hz, 550 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer interface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRS-232 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable calibration (NIST)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eData at –30°C, 0°C, 50°C, 100°C, and 155°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eSpecifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cb\u003eBuilt-in Reference Input\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–200°C to 962°C (–328°F to 1764°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 Ω to 400 Ω, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacterizations\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 Callendar-Van Dusen (CVD): R\u003csub\u003e0\u003c\/sub\u003e, a, b, d\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 Ω to 20 Ω: 0.0005 W\u003cbr\u003e20 Ω to 400 Ω: 25 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature accuracy\u003cbr\u003e(does not include probe uncertainty)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e10 Ω PRTs\u003c\/b\u003e:\u003cbr\u003e±0.013°C at 0°C\u003cbr\u003e±0.014°C at 155°C\u003cbr\u003e±0.019°C at 425°C\u003cbr\u003e±0.028°C at 700°C\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e25 Ω and 100 Ω PRTs:\u003c\/b\u003e\u003cbr\u003e±0.005°C at –100°C\u003cbr\u003e±0.007°C at 0°C\u003cbr\u003e±0.011°C at 155°C\u003cbr\u003e±0.013°C at 225°C\u003cbr\u003e±0.019°C at 425°C\u003cbr\u003e±0.027°C at 661°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 Ω to 20 Ω: 0.0001 Ω\u003cbr\u003e20 Ω to 400 Ω: 0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement period\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe connection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4-wire with shield, 5-pin DIN connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNVLAP accredited (built-in reference input only), NIST-traceable calibration provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke Calibration","offers":[{"title":"Default Title","offer_id":42164728922301,"sku":"9171","price":0.0,"currency_code":"NGN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/products\/9172-1500x1000.jpg?v=1740581383","url":"https:\/\/www.powerpro.ng\/products\/fluke-calibration-9171-field-metrology-well","provider":"Powerpro Company Limited","version":"1.0","type":"link"}