{"product_id":"fluke-calibration-6270a-pressure-controller-calibrator","title":"Fluke Calibration 6270A Pressure Controller \/ Calibrator","description":"\u003ch1\u003eFluke Calibration 6270A Pressure Controller \/ Calibrator\u003c\/h1\u003e\u003ch2 data-mce-fragment=\"1\"\u003eCalibrate a wide workload—quickly, accurately, dependably\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 6270A features pressure ranges from low differential pressure to 20 MPa (3000 psi), which covers the requirements of most gauges and sensors. Three levels of accuracy, 0.02 % FS, 0.01 % reading from 50% to 100 % or 0.01 % reading from 30 % to 100 %, let you balance your need for accuracy with the limits of your budget.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThanks to its modular design, the 6270A is flexible enough that you can install modules with different accuracy classes within the same chassis. You can buy the highest level of accuracy for the pressure ranges that require it and a lower, more economical level of accuracy where applicable.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 6270A’s accuracy specifications are provided in full and supported by a Technical Note that details its measurement uncertainty, so you know exactly what you are getting. As with all Fluke Calibration instruments, these specifications are conservative, complete, and dependable.\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eCutting edge technology and performance\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThree families of pressure measurement modules provide three levels of performance that let you set up a system that matches your needs for accuracy and value.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" data-mce-fragment=\"1\" bordercolor=\"#c5cdd2\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth width=\"33%\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eGood: PM200 Pressure Measurement Modules\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth width=\"33%\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBetter: PM500 Pressure Measurement Modules\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth width=\"33%\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBest: PM600 Measurement Modules\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e0.02% FS specification makes it ideal for calibrating or testing pressure dial gauges, lower accuracy transmitters, or pressure switches\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRugged silicon pressure sensor design allows for faster control\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEconomic price point helps facilitate the purchase of backup modules, making sure you are never down for calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHighly characterized and linearized silicon pressure sensor provides an economical way of making accurate pressure measurements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e0.01 reading measurement uncertainty from 50% to 100% for most ranges allows for wide workload coverage\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMore than 45 ranges, from low differential pressures up to 20 MPa (3000 psi) to choose from. Your application is covered with this wide flexibility in configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke Calibration Quartz Reference Pressure Transducer (Q-RPT) technology provides precise measurement with long term stability\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e0.01% reading measurement uncertainty from 30% to 100% of the modules’ span allows for extremely wide workload coverage\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOnboard barometer included with absolute mode modules, allowing them to be used in both absolute and gauge mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eWide rangeability assures wide workload coverage\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe standard pressure control module can handle a wide range of pressures. A flexible range control module is also available if you need to handle an even wider range.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 6270A features pulse-width-modulated control, a proven technology that enables it to deliver wide rangeability, the ratio of the maximum to the minimum specified measured value at which the instrument performs correctly. A wide rangeability is what enables you to calibrate a wide workload.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003ctable class=\"table\" cellspacing=\"0\" cellpadding=\"3\" border=\"1\" bordercolor=\"#c5cdd2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#e9eff4\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003ePower requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 V ac to 240 V ac, 47 Hz to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eT2A 250 V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eMax power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eOperating ambient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e15 °C to 35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 °C to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" rowspan=\"2\"\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOperating: \u0026lt;80 % to 30 °C, \u0026lt;70 % to 40 °C, \u0026lt;40 % to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage: \u0026lt;95 %, non-condensing. A power stabilization period of four days may be required after extended storage at high temperature and humidity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eMIL-T-28800E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAltitude (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIEC 60529: IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIEC 61010-1, Installation Category II, Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eWeight (Chassis only)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e13 kg (28.5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" rowspan=\"3\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eHeight: 147 mm (5.78 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWidth: 454 mm (17.79 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDepth 488 mm (19.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eRack mount dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3U-19 inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eWarm up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e15 minutes after power up or module installation, when items previously stored within Operating Ambient Temperature Range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eISO\/IEC 17025 accreditation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#e9eff4\"\u003e\u003cstrong\u003eControl specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eControl precision (dynamic mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePM200-BG2.5K range ± 0.005% range\u003cbr\u003ePM500, ranges ≤ 20 kPa (80 inH20) ± 0.002% range\u003cbr\u003eAll other ranges ± 0.001% range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eControl turndown\u003csup\u003e1\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10:1  (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eLow control point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 kPa (0.15 psi) absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#e9eff4\"\u003e\u003cstrong\u003eSupply pressure requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eClean dry N2  or air – Industrial grade nitrogen, 99.5 %+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eParticulate contamination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e≤ 1.25 micrometer (50 microinches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eMaximum moisture content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-50 °C dew point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eMaximum hydrocarbon content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#e9eff4\"\u003e\n\u003cstrong\u003eVacuum supply requirements\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e(when operating near or sub-atmospheric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e\u0026gt;50 liters per minute capacity with Auto Vent feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eAppropriate protections for High Pressure Gauge work system exhaust gas will pass through the Vacuum supply system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#e9eff4\"\u003e\u003cstrong\u003eInterface\/communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003ePrimary remote interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIEEE 488.2, Ethernet, RS232, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSystem connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSupports interconnection of two or three systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSwitch test connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eStandard 4 mm jack:\u003cbr\u003eNominal 24 v dc isolated drive Maximum 30 V dc w.r.t. chassis ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAux drivers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e4 external solenoid drivers\u003cbr\u003e24 V dc drive (maximum drive 6 W continuous per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e\n\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eControl turndown is defined as the relationship between the provided supply pressure and the appropriate supply pressure for the range. For example, a unit with a 7 MPa (1000 psi) and 700 kPa range (100 psi) with a supply pressure of 7.7 MPa (1100 psi) will provide control precision of 0.001% range because 7 MPa is 10 times greater than 700 kPa. A system with ranges of 20 MPa (3000 psi) and 700 kPa (100 psi) with supply pressure of 22 MPa (3300 psi) will have 0.001% range control precision on the 20 MPa range but only 0.003% control precision on the 700 kPa range. Control precision of 0.001% on the low range can be achieved by reducing the supply pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke Calibration","offers":[{"title":"Default Title","offer_id":42164742586557,"sku":"6270A","price":0.0,"currency_code":"NGN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/products\/Fc-6270a_01a_c.png?v=1740570161","url":"https:\/\/www.powerpro.ng\/products\/fluke-calibration-6270a-pressure-controller-calibrator","provider":"Powerpro Company Limited","version":"1.0","type":"link"}