{"product_id":"fluke-1775","title":"Fluke 1775","description":"\u003ch4\u003eFluke 1775\/BASIC Offers\u003c\/h4\u003e\n\u003cp\u003eMake data capture as reliable and easy as possible with the power quality analyzer that features instrument powering from the measurement circuit, automatic connection check, and correction.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe 1775\/BASIC Power Quality Analyzer replaces the discontinued 435-II Power Quality and Energy Analyzer\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatically measure power and power quality parameters\u003c\/li\u003e\n\u003cli\u003ePower system connection and instrument setup autocorrection\u003c\/li\u003e\n\u003cli\u003eInstrument automatically detects error in voltage and current wiring, providing correction without rewiring\u003c\/li\u003e\n\u003cli\u003eHigh resolution touchscreen\u003c\/li\u003e\n\u003cli\u003eCapacitive touchscreen allows use with PPE (double gloved hands), providing clear results in seconds\u003c\/li\u003e\n\u003cli\u003ePower quality health summary: automatically evaluate power quality inputs against the EN 50160 electrical standard, providing detailed troubleshooting of power quality problem areas\u003c\/li\u003e\n\u003cli\u003eHarmonics: multiple methods of harmonic analysis provide users with the data they increasingly need with basic fundamental to 50 integer harmonics, 2 to 9 kHz for IEC61000-4-30 Annex A compliance and harmonics to 30 kHz harmonics to discover the effects of inverters on the network\u003c\/li\u003e\n\u003cli\u003eCritical power quality data is captured as soon as you begin a session, without extensive setup or selections\u003c\/li\u003e\n\u003cli\u003eIntuitive user interface makes it easy to navigate between measurement parameters like V\/A\/Hz, power, dips and swells, harmonics, or PQ health at the push of a button\u003c\/li\u003e\n\u003cli\u003eCapture damaging high-speed transients so you can mitigate their effects before equipment fails\u003c\/li\u003e\n\u003cli\u003eAnalysis and reporting comes standard with Fluke Energy Analyze Plus software giving you the ability to create customized reports, or leverage built-in one-click reporting to industry standards like EN 50160, IEEE 519 and GOST 33073\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Update V3.1.1:\u003c\/strong\u003e Introducing high-resolution Fast Trend data logging on the Fluke 1775 and 1777, capture measurements every 10 cycles at 50 Hz or 12 cycles at 60 Hz for more detailed power quality analysis through Fluke Energy Analyze Plus. The update also improves voltage and frequency calculations, enhances DC offset accuracy, and corrects occasional minimum\/maximum reading errors. Users must have Fluke Energy Analyze Plus version 3.14 or later to access the new Fast Trend data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBasic power studies\u003c\/li\u003e\n\u003cli\u003eBasic power quality studies\u003c\/li\u003e\n\u003cli\u003eAdvanced power studies\u003c\/li\u003e\n\u003cli\u003eAdvanced power quality studies\u003c\/li\u003e\n\u003cli\u003eEnergy surveys\u003c\/li\u003e\n\u003cli\u003eLoad studies\u003c\/li\u003e\n\u003cli\u003eCapture events\u003c\/li\u003e\n\u003cli\u003eView event waveform data on screen\u003c\/li\u003e\n\u003cli\u003eMains signal monitoring\u003c\/li\u003e\n\u003cli\u003eHarmonic surveys\u003c\/li\u003e\n\u003cli\u003eNuisance circuit breaker tripping\u003c\/li\u003e\n\u003cli\u003ePower utility power quality surveys\u003c\/li\u003e\n\u003cli\u003eDiscovery of equipment failures caused by transients\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span4 text-center\"\u003e\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1770-series-application1.jpg\" class=\"\" alt=\"Fluke 1700 Series application shot\" data-pagespeed-url-hash=\"3611332246\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"span4 text-center\"\u003e\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1770-series-application2.jpg\" class=\"\" alt=\"Fluke 1700 Series application shot\" data-pagespeed-url-hash=\"3905832167\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"span4 text-center\"\u003e\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1770-series-application3.jpg\" class=\"\" alt=\"Fluke 1700 Series application shot\" data-pagespeed-url-hash=\"4200332088\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic measurements. More flexibility. Better power quality troubleshooting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe three-phase power quality analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord. With the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic measurement capture\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you’re performing a quick system check or a detailed power quality study, consistent data is key. The power quality analyzer offers a unique automatic measurement capture system that helps ensure you’re collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you’re working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltimate measurement confidence\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe three-phase power quality analyzers are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.\u003c\/p\u003e\n\u003cp\u003eThe ‘PQ Meter’ function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":68333751140541,"sku":"Fluke 1775","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/files\/fluke-1775-basic-power-quality-analyzer.jpg?v=1794586745","url":"https:\/\/www.powerpro.ng\/products\/fluke-1775","provider":"Powerpro Company Limited","version":"1.0","type":"link"}