{"product_id":"allen-bradley-189-ar20-mcb-accessory-auxiliary-contact","title":"Allen-Bradley 189-AR20 MCB Accessory Auxiliary Contact","description":"\u003ch1\u003eAllen-Bradley 189-AR20 MCB Accessory Auxiliary Contact\u003c\/h1\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003e1492 SP Series - Accessories\u003c\/h3\u003e\u003cbr\u003e\u003cdiv\u003e\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003eProfessional range of Allen Bradley general purpose MCBs accessories from the 1492 series. Accessories include auxiliary contacts, single phase busbars, busbar end caps, protective shrouds, shunt trips and terminal power feeds. All accessories are highly reliable and excellent quality.\u003c\/div\u003e\u003c\/div\u003e\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003e\u003cstrong\u003eAllen Bradley Auxiliary Release Circuit Trip For Use With 1492-D DC Circuit Breaker, 2NO - 189-AR20\u003c\/strong\u003e\u003c\/h3\u003e\u003cbr\u003e\u003cdiv\u003e\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003eEnhance circuit protection in your electrical systems with this auxiliary release circuit trip from Rockwell Automation's Allen Bradley range. This component works with 1492-D DC (direct current) circuit breakers to cut off current supply to your setup in the event of a fault, enhancing electrical safety. Its compact dimensions of 85 (length) x 8.8 (width) x 74mm (height) make it a good choice for installation in areas where space is limited. The thermoplastic housing material provides resistance to impact for use in harsh environments.\u003c\/div\u003e\u003c\/div\u003e\u003cbr\u003e\u003cdiv\u003e\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003e• Designed for DIN rail mounting for quick and simple installation\u003cbr\u003e• Maximum current rating of 2A for energy-efficient operation\u003cbr\u003e• Broad operating temperature range of -25°C to +55°C for use in demanding environments\u003c\/div\u003e\u003c\/div\u003e\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cbr\u003e\u003cdiv\u003e\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003e• CE (Conformitè Europëenne)\u003cbr\u003e• CSA (Canadian Standards Association)\u003cbr\u003e• CCC (China Compulsory Certificate)\u003c\/div\u003e\u003c\/div\u003e\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003e\u003cstrong\u003eHow do I use this auxiliary contact safely?\u003c\/strong\u003e\u003c\/h3\u003e\u003cbr\u003e\u003cdiv\u003e\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003eIt's important to note that you can't install more than two auxiliary contacts per circuit breaker. You also shouldn't combine it with shunt trips or changeover (CO) type contacts to prevent damage to your electrical circuits..\u003c\/div\u003e\u003c\/div\u003e\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003e\u003cbr\u003e\u003c\/h3\u003e\u003cdiv\u003e\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003eAllen Bradley MCBs\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"sc-VigVT gBHNjZ\"\u003e\u003ch2 font-size=\"6\" data-testid=\"specifications-title\" class=\"sc-bdVaJa YmDnE\"\u003eSpecifications\u003c\/h2\u003e\u003c\/div\u003e\u003ctable data-testid=\"specification-attributes\" class=\"sc-jzJRlG dQhhps\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003eAttribute\u003c\/td\u003e\n\u003ctd\u003eValue\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eRange\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eBulletin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e189-AR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eFor Use With\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e1492-D DC Circuit Breaker, 188 Regional Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eType\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eAuxiliary Release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eRated Control Voltage\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e30 V dc, 50 V dc, 230 V ac, 400V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"rockwell automations","offers":[{"title":"Default Title","offer_id":37671743946941,"sku":"189-AR20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/products\/R1251546-01.jpg?v=1673366286","url":"https:\/\/www.powerpro.ng\/products\/allen-bradley-189-ar20-mcb-accessory-auxiliary-contact","provider":"Powerpro Company Limited","version":"1.0","type":"link"}