{"product_id":"abb-compact-home-sh200-mcb-3p-poles-32a-curve-c-440v-ac-6-ka-breaking-capacity","title":"ABB Compact Home SH200 MCB, 3P Poles, 32A Curve C, 440V AC, 6 kA Breaking Capacity","description":"\u003ch1\u003eABB Compact Home SH200 MCB, 3P Poles, 32A Curve C, 440V AC, 6 kA Breaking Capacity\u003c\/h1\u003e\u003cp\u003ePowerpro company Limited is the distributor, supplier and service provider of ABB's ( Test Equipment Product Sales,  Test Equipment Calibration, Test Equipment Rentals and  Product Training) in Nigeria.\u003c\/p\u003e \u003csection data-testid=\"descriptive-content-container\"\u003e\u003cdiv class=\"sc-dnqmqq bXVrbq\"\u003e\u003ch2 font-size=\"6\" data-testid=\"descriptive-content-header\" class=\"Box-sc-1a4tiu7-0 cviPht\"\u003eProduct Details\u003c\/h2\u003e\u003c\/div\u003e\n\u003ch3 data-testid=\"descriptive-content-main-header\"\u003eABB System M Pro S200 Triple Pole Type C 6 kA\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003eABB System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electro mechanic tripping mechanism for short circuit protection. All MCBs of the product range S200M comply with IEC\/EN 60898-1 and IEC\/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003e•\tExtra-wide and complete range of MCBs to cover most applications and markets\u003cbr\u003e•\tSpace and time saving thanks to the unique bottom-fixing auxiliary contact\u003cbr\u003e•\tMeeting worldwide standards\u003cbr\u003e•\tFor domestic or small commercial installations up to 6 kA breaking capacity\u003cbr\u003e•\tIEC\/EN 60898-1, IEC\/EN 60947-2 \u003cbr\u003e•\t Triple pole\u003cbr\u003e•\tOperating temperature range of -25°C to +55°C\u003cbr\u003e•\tMax. operating voltage 440Vac\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003eStandards\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003eIEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar\u003cbr\u003eInstallations. In the UK traditionally known as miniature circuit breakers \u003cbr\u003e(MCB’s).\u003cbr\u003eIEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar\u003cbr\u003eInstallations. In the UK traditionally known as moulded case circuit breakers \u003cbr\u003e(MCCB’s) and also air circuit breakers (ACB’s).\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003eQ: What Tripping Curves C\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003eA: Curve C: Tripping:  5 to 10 times the rated current\u003cbr\u003eApplications: protection of circuits and general applications\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003eNote\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003eThese are an economy range of MCB's and as such do not accept common accessories, these items will not fit compact boards (System Pro-M).\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3 data-testid=\"descriptive-content-main-header\"\u003eNote\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003eThese are an economy range of MCB's and as such do not accept common accessories, these items will not fit compact boards (System Pro-M).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-testid=\"descriptive-content-main-header\"\u003eStandards\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003eBS EN 60898\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-testid=\"descriptive-content-main-header\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"sc-cJSrbW iYUwDF\"\u003eABB Compact Home\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"sc-dnqmqq bXVrbq\"\u003e\u003chr class=\"sc-iwsKbI dYCnuy\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003cdiv class=\"sc-dnqmqq bXVrbq\"\u003e\u003ch2 font-size=\"6\" data-testid=\"specifications-title\" class=\"Box-sc-1a4tiu7-0 cviPht\"\u003eSpecifications\u003c\/h2\u003e\u003c\/div\u003e\n\u003ctable data-testid=\"specification-attributes\" class=\"sc-gqjmRU dvSZoQ\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003eAttribute\u003c\/td\u003e\n\u003ctd\u003eValue\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eTripping Characteristics\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eRated AC Voltage\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eModel Number\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eSH203-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eSH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eRange\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eCompact Home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eBreaking Capacity at Maximum Voltage Rating\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eCircuit Breaker Type\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eMCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003eDIN Rail Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eWidth\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e52.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eLength\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e85mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eDepth\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e69mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/section\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42202029621437,"sku":"2CDS213001R0324  SH203-C32","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/products\/F5398374-01.jpg?v=1739955930","url":"https:\/\/www.powerpro.ng\/products\/abb-compact-home-sh200-mcb-3p-poles-32a-curve-c-440v-ac-6-ka-breaking-capacity","provider":"Powerpro Company Limited","version":"1.0","type":"link"}