{"title":"Electrical Calibration","description":"","products":[{"product_id":"fluke-3000-fc-series-wireless-multimeter","title":"Fluke 3000 FC Series Wireless Multimeter","description":"\u003ch1\u003eFluke 3000 FC Series Wireless Multimeter\u003c\/h1\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 3000 FC with Fluke Connect provides all the facts right in the field.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith its precision, reliability, and ease of use, the Fluke 3000 FC Wireless Multimeter has all the essential electrical and electronic troubleshooting features professional technicians need. It gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging, plus a frequency, capacitance, resistance, continuity and diode measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReduces arc flash risk\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndependently tested for safe use in CAT IV 600V\/CAT III 1000 V environments, the Fluke 3000 FC DMM and Fluke Connect wireless modules put tools, not your body, near live electrical panels. Just de-energize the cabinet; open the panel while wearing PPE; and connect the remote modules—voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC from a safe distance up to away. You can view the meter measurement, plus readings from up to three wireless modules all on the same screen. And by separating yourself from hazardous measurement situations you’ll reduce the risk of arc flash.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGives the full picture in real time.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith Fluke Connect-enabled tools you can connect multiple remote modules in different parts of the system and view the interaction between remote test points on a single screen, in real time. Create and email reports right from the field, or download the data to a PC for further analysis. The Fluke 3000 FC connects to your smartphone through Bluetooth so you can send measurement data from the meter to your phone and share it with your team anytime, from anywhere.\u003c\/p\u003e\n\u003ch2 class=\"features-title\" data-mce-fragment=\"1\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\" data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFull featured multimeter that also reads results wirelessly from remote Fluke Connect® wireless modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeasures AC and DC voltage to 1000 V, AC and DC current, and temperature\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShows up to four readings simultaneously on a bright white backlit display\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSends measurement data to your smartphone\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSafety rated CAT III 1000 V, Cat IV 600 V; IP54\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecord measurements over time and monitor changes live on your phone.\u003c\/li\u003e\n\u003cli\u003eShare the results using Fluke Cloud™ storage and ShareLive™ video call.\u003c\/li\u003e\n\u003cli\u003eProvides True-RMS voltage and current measurements with 6000-count resolution\u003c\/li\u003e\n\u003cli\u003eShare results with remote team members instantly with ShareLive™ video call\u003c\/li\u003e\n\u003cli\u003eIncludes continuity, resistance, diode test, capacitance, and frequency tests, plus MIN\/MAX recording\u003c\/li\u003e\n\u003cli\u003eProvides 0 09% basic accuracy\u003c\/li\u003e\n\u003cli\u003eWorks with a standard amp clamp or with a flexible iFlex clamp\u003c\/li\u003e\n\u003cli\u003eShows meter measurement and readings from up to three modules simultaneously\u003c\/li\u003e\n\u003cli\u003eAllows mixing and matching modules to meet your specific measurement needs\u003c\/li\u003e\n\u003cli\u003eCurrent, voltage and temperature modules are available separately or in Fluke Connect kits\u003c\/li\u003e\n\u003cli\u003eRuns on three AA Alkaline batteries, providing 250 hours minimum battery life\u003c\/li\u003e\n\u003cli\u003eComes with three-year standard warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"features-title\" data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\" data-mce-fragment=\"1\"\u003e\n\u003ch2\u003eSpecifications: Fluke 3000 FC Series Wireless Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange¹ \/ resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003cbr\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e45 Hz to 500 Hz\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. AC voltage ranges are specified from 1% of range to 100% of range.\u003cbr\u003e2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor \u0026lt; 1.5 at 1000 V.\u003cbr\u003e3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.\u003cbr\u003e4. Do not exceed 107 V-Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage, Continuity, Resistance, Diode Test and Capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.09% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eV\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.09% + 2\u003cbr\u003e0.15% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e)))\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eMeter beeps at \u0026lt; 25 Ω, beeper detects opens or shorts of 250 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e60.00 kΩ \/ 0.1 kΩ\u003cbr\u003e600.0 kΩ \/ 0.001 MΩ\u003cbr\u003e50.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003cbr\u003e0.5% + 1\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eµF\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange \/ resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF\u003csup\u003e1 \/\u003cspan\u003e \u003c\/span\u003e\u003c\/sup\u003e1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.2% + 2\u003cbr\u003e10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC and DC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA AC\u003cbr\u003e(45 Hz to 1 kHz)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eRange\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ resolution\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003csup\u003e3\u003cspan\u003e \u003c\/span\u003e\u003c\/sup\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eRange\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ resolution\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. All AC current ranges are specified from 5% of range to 100% of range.\u003cbr\u003e2. Input burden voltage (typical): 400 mA input 2 mV\/mA.\u003cbr\u003e3. 400.0 mA accuracy specified up to 600 mA overload.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \/ resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 kHz\u003cbr\u003e99.99 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInput Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-1-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-2-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB, DC to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-3-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOpen Circuit Test Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-4-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 V DC\u003cbr\u003e\u0026lt; 0.9 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-5-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e2.000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003emA Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFused, 44\/100 A, 1000 V FAST Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 mA overload for 2 minutes maximum, 10 minutes rest minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMIN\/MAX Recording Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 12 counts for changes \u0026gt; 350 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 40 counts for changes \u0026gt; 900 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V DC or AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eΩ fuse protection from A inputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44 A (44\/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay (LCD)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eUpdate rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts, amps, ohms\u003c\/td\u003e\n\u003ctd\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree AA Alkaline batteries, NEDA 15A IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF communications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHZ ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRF communication range\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOpen air, unobstructed\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, sheetrock wall\u003c\/td\u003e\n\u003ctd\u003eUp to 6.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, concrete wall, or steel electrical enclosure\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 3.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 X (specified accuracy) \/ °C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90% (0°C to 35°C)\u003cbr\u003e0% to 75% (35°C to 40°C)\u003cbr\u003e0% to 45% (40°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003cbr\u003eEMI, RFI, EMC, RF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326–1:2006, EN 61326–2–2:2006\u003cbr\u003eETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489\u003cbr\u003eV1.8.1:2008\u003cbr\u003eFCC Part 15 Subpart C Sections 15.207, 15.209, 15.249\u003cbr\u003eFCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eANSI \/ ISA 61010–1 \/ (82.02.01): 3rd edition\u003cbr\u003eCAN \/ CSA-C22.2 No 61010-1-12: 3rd edition\u003cbr\u003eUL 61010–1: 3rd edition\u003cbr\u003eIEC \/ EN 61010–1:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, FCC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e340 g (12 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003eNot compatible with Fluke CNX test tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":43217006198973,"sku":"Fluke 3000 FC","price":0.0,"currency_code":"NGN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/files\/f-3000fc_03a_h-1500x1000-removebg-preview.png?v=1740581015"},{"product_id":"fluke-t3000-fc-wireless-temperature-module","title":"Fluke t3000 FC Wireless Temperature Module","description":"\u003ch1 id=\"fluke-product-display-title\" data-mce-fragment=\"1\" itemprop=\"name\"\u003eFluke t3000 FC Wireless Temperature Module\u003c\/h1\u003e\n\u003ch2\u003eProduct overview: Fluke t3000 FC Wireless Temperature Module\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eSee it. Save it. Share it.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll the facts, right in the field. The Fluke t3000 FC Wireless K-Type Temperature Module is one member of a family of wireless test tools that let you share test data using the Fluke Connect® app with ShareLive™ video call.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cp\u003eThe Fluke t3000 FC Wireless K-Type Temperature Module wirelessly relays measurements to other Fluke Connect® enabled master units, listed below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 3000 FC DMM\u003c\/li\u003e\n\u003cli\u003eFluke Ti200\/300\/400 Infrared Camera\u003c\/li\u003e\n\u003cli\u003ePC via optional pc3000 FC Adapter\u003c\/li\u003e\n\u003cli\u003eFluke Connect Mobile app\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the Fluke t3000 FC Wireless K-Type Temperature Module you can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse as a standalone meter or as part of the system\u003c\/li\u003e\n\u003cli\u003eLogging function for recording and saving up to 65,000 readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eFluke Connect Wireless Test Tools put tools, not your body, near live electrical panels. It's simple. Connect the t3000 FC wireless temperature module, or any of the other Fluke Connect remote modules, and read the results on the Fluke Connect Wireless Multimeter or a portable PC from a safe distance.\u003c\/p\u003e\n\u003cp\u003eBetter still, the Fluke Connect test tools can send measurement data to your smartphone, so you can save and share measurements from the field with your team anytime, from anywhere.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDon't get bogged down while isolating intermittent electrical faults\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTiming is everything when trying to find an intermittent problem and the hard part is, it doesn't always show up when you have your meter connected. We've solved that problem with Fluke Connect – leave your remote modules connected to log measurements and walk away to address other issues. You can then download the data for further analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWork safely near electrical panels while wearing less PPE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePersonal protective equipment (PPE) can save your life, but it's bulky, hot and hard to work in. With Fluke Connect, there's no need to work in front of live open panels or moving\/hazardous machinery.\u003c\/p\u003e\n\u003cp\u003ePicture having the ability to access live readings without being exposed to the live panel. It's easy. Just de-energize the cabinet, open the panel while wearing PPE and connect one or more t3000 FC modules. Close the cabinet, re-energize and let the Fluke Connect system work, reducing the risk of arc flash by separating yourself from hazardous measurement situations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTesting 3-phase is now faster and cheaper\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen your cabinet is de-energized, attach a Fluke Connect voltage module to each phase. Close, re-energize and start taking readings. What used to take hours and use costly equipment can be done in minutes with an affordable Fluke Connect wireless system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTake 3-phase measurements in 1\/3 the time. Add your laptop and go from logging to analysis and diagnosis.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can solve problems faster by seeing live measurements from multiple test points on a single screen. Using t3000 FC temperature modules, you can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpot temperature differences between three phases in 1\/3 the time of previous methods.\u003c\/li\u003e\n\u003cli\u003eSend data to your laptop and go from logging to analysis and diagnosis.\u003c\/li\u003e\n\u003cli\u003eRecord over time to monitor circuit load changes for an hour, a shift or a week.\u003c\/li\u003e\n\u003cli\u003eUse the Fluke Connect wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data.\u003c\/li\u003e\n\u003cli\u003ePerform for analysis with your PC and share the results using Fluke Cloud™ storage and ShareLive™ video call. View data or graphs to get input from team members.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke t3000 FC Wireless Temperature Module\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange K-Type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-200°C to 1372°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±[0.5% + 0.5°C] counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput terminals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eK-type mini\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD w\/backlight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 ½ digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog rate\/interval\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 sec minimum\/adjustable by PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA, NEDA 15 A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRecord up to 65,000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF communications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHZ ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eRF communication range\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOpen air, unobstructed\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, sheetrock wall\u003c\/td\u003e\n\u003ctd\u003eUp to 6.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, concrete wall or steel electrical enclosure\u003c\/td\u003e\n\u003ctd\u003eUp to 3.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01% of reading +0.03°C per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90% at 35°C, 75% at 40°C, 45% at 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, CAT I, 3rd edition Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e.22 kg (8 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003eNot compatible with Fluke CNX test tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":43217048076477,"sku":"FLK-T3000FC","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/files\/F_t3000fc_03a_h_1500x1000_1-removebg-preview_1.png?v=1740581013"},{"product_id":"fluke-v3000-fc-wireless-ac-voltage-kit","title":"Fluke v3000 FC Wireless AC Voltage Kit","description":"\u003ch1 id=\"fluke-product-display-title\" data-mce-fragment=\"1\" itemprop=\"name\"\u003eFluke v3000 FC Wireless AC Voltage Kit\u003c\/h1\u003e\n\u003ch2\u003eProduct overview: Fluke v3000 FC Wireless AC Voltage Kit\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke v3000\u003cspan\u003e \u003c\/span\u003eFC WirelessVoltage Kit is part of the Fluke Connect team of wireless test tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect the v3000 FC Wireless AC Voltage Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.\u003c\/p\u003e\n\u003cp\u003eYou'll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect® modules as a system for multiple measurements.\u003c\/p\u003e\n\u003cp\u003eFrom short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless Temperature Module captures up to 65,000 sets of time stamped min\/max\/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.\u003c\/p\u003e\n\u003cp\u003eNow you can take readings on moving machinery, with only the measurement module in harm's way.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke FC Wireless v3000 Voltage Kit provides measurement of many common electrical parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurements to 1000 V\u003c\/li\u003e\n\u003cli\u003eAC and DC current with 0.01 mA resolution\u003c\/li\u003e\n\u003cli\u003eContinuity, resistance, diode test, capacitance and frequency measurements\u003c\/li\u003e\n\u003cli\u003eMIN\/MAX recording\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, Cat IV 600 V; IP54\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the Fluke v3000 FC Wireless AC Voltage Module you can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure up to 1000 V True-RMS AC\u003c\/li\u003e\n\u003cli\u003eUse as a standalone meter or as part of the system\u003c\/li\u003e\n\u003cli\u003eUse the logging function for recording and saving up to 65,000 readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":43217453121725,"sku":"FLK-v3000 FC Kit","price":0.0,"currency_code":"NGN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0477\/6738\/8316\/files\/fluke_v3000_fc-wireless_ac_c-1500x1000-removebg-preview.png?v=1740581013"}],"url":"https:\/\/www.powerpro.ng\/collections\/electrical-calibration.oembed","provider":"Powerpro Company Limited","version":"1.0","type":"link"}